verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$85.41 $91.21Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W

GFC30015MC2W is an AirTAC G-series two-unit F.R.L. set: a filter-regulator in one body plus a separate lubricator, so the air is filtered, regulated and oil-mist lubricated in one installation. This 300-size configuration has a 1/2 in PT port, a manual drain on the polycarbonate filter bowl, a 5 um (W) filter element and a round external gauge reading in psi. Maximum working pressure is 1.0 MPa (145 psi) and, with the manual-drain version, the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi).

This is a genuine AirTAC part. The GFC family is offered in 200, 300, 400 and 600 sizes with ports from 1/8 in to 1 in, a 40 um standard or 5 um W element, differential-pressure, automatic or manual drains, and square or round gauges in MPa, psi or bar scales; G (BSPP) and NPT threads are catalogue options alongside the standard PT. Flow is published as curves rather than a single rating, so we confirm sizing and datasheet figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W Is Used

precision_manufacturing

CNC machining center

Point-of-use F.R.L. set feeding the tool-changer and chip-conveyor cylinders of a CNC machining center, where the 5 um element protects fine pilot valves from water and particulate carryover.

conveyor_belt

Carton sealing line

Filtered, regulated and lubricated air supply to the cylinder-driven tuck-and-fold heads on a carton sealing and taping line, with the lubricator keeping the sealing cylinders running smoothly.

build

Automotive assembly stations

Lubricated air feed to impact wrenches and nutrunners at automotive final-assembly stations, with the regulator set at the station's working pressure and read off the psi gauge.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W the Right Set?

Choose the 300 size with 1/2 in PT port when your circuit is built on 1/2 in pipework and you want the mid-range step of the G-series; step up to 400 or 600 for larger ports or down to 200 for 1/8-1/4 in lines. The manual drain (M) means the bowl is emptied by hand on a scheduled routine, and it widens the regulator range to 0.05-0.9 MPa (7-130 psi); automatic drain (A) is the choice when you want drainage without operator rounds. The W element at 5 um suits finer point-of-use protection, while the standard element is 40 um for general line duty. The round psi gauge here is the external gauge option; square embedded gauges and MPa or bar scales can be ordered instead, as can G or NPT threads. Operating temperature is -5 to 70 C (non-freezing). Flow is published as curves, not one rated number, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W FAQ

Flow for G-series units is published as characteristic curves rather than one rated figure, so we do not quote a single l/min or SCFM number. Tell us your application and we will pull the GFC300 datasheet curves and confirm the sizing on request before you order.

Manual drain requires someone to open the bowl drain by hand, but it widens the regulator range to 0.05-0.9 MPa (7-130 psi) versus 0.15-0.9 MPa (20-130 psi) with the default differential-pressure or automatic drains. Pick M only where a drain routine already exists; otherwise order the automatic-drain version.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MC2W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30015MC2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.