verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$61.60 $66.81Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW

The AirTAC GFC series is a two-piece air preparation set: a filter regulator plus a separate lubricator, so one installation filters, regulates and lubricates the compressed air supply. This GFC30015MLNW is the size 300 unit with PT1/2 ports (PT thread is the standard), a manual drain bowl, the L low-pressure regulator type, no gauge fitted (N), and the fine 5 um (W) filter element. Maximum working pressure is 1.0 MPa (145 psi), the manual-drain regulator setting range is 0.05-0.9 MPa (7-130 psi), and operating temperature is -5 to 70 C (non-freezing). The size 300 bowls on both the filter regulator and the lubricator are PC (polycarbonate).

This is a genuine AirTAC part. The G series spans sizes 200, 300, 400 and 600, with PT, G(BSPP) or NPT threads, automatic, manual or differential-pressure drains, 40 um or 5 um (W) elements, gauge variants and optional brackets across the range. Flow is published as curves rather than a single rating, so ask us to confirm sizing and full datasheet figures for your application before ordering.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW Is Used

local_shipping

Trailer brake-test and air-tool station

On a truck workshop station, the set cleans shop air to 5 um for test gauges and solenoid valves, sets the low regulated test or tool pressure, and lubricates impact tools at the bay - with readings taken from the station's own master gauge.

engineering

Robotics end-of-arm gripper supply

Feeding a robot cell's gripper and sensing valves, the fine 5 um element protects small pilot orifices while the regulator holds the low, stable pressure the gripper was sized for and the lubricator conditions the actuator air.

air

Air bearing and air-jet cleaning bench

At a bench using air bearings or precision air-jet nozzles, clean 5 um air and a steady low regulated pressure matter; the lubricator covers downstream tool use, and the no-gauge build suits benches with their own panel gauges.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW the Right Set?

Start with size and port: 200 to 600 covers small point-of-use drops up to large machine headers, and stepping up a size gives a larger port and more flow capacity. This unit is size 300 with PT1/2 ports; G and NPT threads are catalogue options if your piping is BSPP or NPT. The W in this code selects the 5 um element instead of the standard 40 um grade, for cleaner air to precision valves and actuators. Drain type matters: this M code is the manual drain variant, which also widens the regulator setting range to 0.05-0.9 MPa (7-130 psi); automatic (A) and differential-pressure (default) drain variants are available. This is the L low-pressure type. The N code means no gauge is fitted; square gauge variants in MPa, psi or bar scales and an external round gauge exist in the same size if you need local indication. Bracket choices are also available.

Because AirTAC publishes flow only as curves, not a single rated figure, ask us to confirm sizing against your actual air demand before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW FAQ

AirTAC publishes flow for this series as performance curves rather than a single rated number, so there is no one figure we can honestly quote here. Send us your line pressure and required air consumption and we will confirm the correct size and the datasheet curve figures on request.

W fits the finer 5 um filter element in place of the standard 40 um grade, and N means the regulator part is supplied without a gauge. If you later need local pressure reading, square-gauge variants in MPa, psi or bar scales and an external round gauge are available in the same size. The manual drain keeps the wider 0.05-0.9 MPa (7-130 psi) regulator setting range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MLNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30015MLNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.