The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$61.60 $66.81Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW

The AirTAC GFC30015MNW is a two-unit air preparation set - filter-regulator plus lubricator - in the 300 size with PT1/2 ports. The W code upgrades the filtration from the 40 um standard to a 5 um element, removing finer particulate and carrying off water before the air is regulated and lubricated. The bowl is drained manually, the regulator in this manual-drain configuration adjusts over 0.05-0.9 MPa (7-130 psi), and the lubricator meters oil mist into the regulated supply. Maximum working pressure is 1.0 MPa (145 psi), the size 300 bowl is PC (polycarbonate), operating temperature is -5 to 70 C (non-freezing), and no gauge is fitted on this code.

This is a genuine AirTAC part from the G series, which runs from size 200 up to 600 with drain-type, filter-grade, gauge and G/NPT thread options. Rated flow is published as curves, not a single figure - ask us and we will confirm the datasheet flow data for your application.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW Is Used

science

Laboratory automation air

Conditions air for sample-handling actuators and small pneumatic drives on lab automation platforms, where the 5 um element supplies cleaner air to precision pneumatic components and the lubricator protects their seals and moving parts.

view_module

Electronics assembly bench

Feeds pick-and-place and screw-driving modules on an electronics assembly bench. The 5 um grade reduces fine particulate reaching the bench's pneumatic tooling, with regulation and oil misting from the paired lubricator unit.

speed

High-cycle packaging machinery

Supplies the air to high-cycle bagging and cartoning machines where fine contamination would shorten valve life: 5 um filtration, a stable regulated pressure for fast cylinder cycling, and lubrication to the machine's air circuit.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW the Right Set?

Pick this code when the finer 5 um element (W) is the deciding factor: it protects sensitive downstream equipment that the standard 40 um grade is not specified for. Everything else decodes as the base 300-size set: PT1/2 port, manual drain (M), no gauge (N), standard regulator. If 40 um is sufficient for your circuit, the plain GFC30015MN is the equivalent. Drain choice across the series is manual, automatic (A) or differential-pressure; gauge and scale variants exist as separate codes. Thread is PT as standard, with G (BSPP) and NPT orderable as catalogue options.

Flow is published as curves rather than a single rating, so let us confirm sizing against your application from the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW FAQ

There is no single published rated flow for the G series - the figures appear as flow curves in the AirTAC datasheet. Give us your line pressure and air demand and we will confirm the relevant flow data for the GFC30015MNW on request.

Choose W when the equipment downstream needs finer filtration than the 40 um standard element provides - for example precision pneumatic tooling, instrumentation or high-cycle valves. This code is otherwise the same set: PT1/2, size 300, manual drain, no gauge, filter-regulator plus lubricator.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30015MNW and will confirm price, stock and lead time — usually within 7-8 hours.