AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$72.94 $78.44Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK

The AirTAC GFC30015MNWK is the fully optioned code of this 300-size two-unit set: a filter-regulator plus a separate lubricator with PT1/2 ports, a 5 um (W) filter element instead of the 40 um standard, and a reverse (check) valve fitted (K). The bowl is drained manually and the regulator in this manual-drain configuration adjusts over 0.05-0.9 MPa (7-130 psi). The lubricator meters oil mist into the filtered, regulated air for downstream actuators and tools. Maximum working pressure is 1.0 MPa (145 psi), the size 300 bowl is PC (polycarbonate), operating temperature is -5 to 70 C (non-freezing), and the N code means no gauge is fitted.

This is a genuine AirTAC part. The GFC series is available in sizes 200 to 600, and each of these options - drain type, filter grade, gauge, reverse valve, G/NPT thread - is chosen through the model code. Flow is published as curves, not a single rated figure, so ask us to confirm the datasheet flow data for your application.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK Is Used

engineering

Robot gripper air circuit

Prepares the PT1/2 air drop feeding end-of-arm grippers on a handling robot: 5 um filtration for the gripper's fine valves, regulated pressure for repeatable grip force, lubrication for the actuator seals, and a fitted check valve where the machine build calls for one.

settings_input_component

Control panel pneumatic interface

Serves as the air preparation point on a machine control panel that branches to several sub-circuits. The set filters to 5 um, regulates the header pressure and oils the downstream circuit, with the K-code check valve fitted as specified on the panel drawing.

build

Automotive assembly tool stations

Conditions air at torque-tool and riveter stations on a vehicle assembly line. The 5 um element keeps fine particles out of the tool supply, the regulator holds the set pressure, and the lubricator mist protects the tool motors between service intervals.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK the Right Set?

This code combines the two most common upgrades on the 300-size set: the W suffix for 5 um filtration and the K suffix for a fitted reverse (check) valve. The remaining decode is the same as the base model - PT1/2 port, manual drain, no gauge, standard regulator. Drop the W if 40 um filtration is enough, drop the K if the circuit has its own check valve, or use the plain GFC30015MN when neither is wanted. Sizes 200, 400 and 600 step the port and flow capacity up or down; thread is PT as standard with G (BSPP) and NPT as orderable options.

Because rated flow appears only as curves in the datasheet, send us your flow and pressure requirements and we will confirm sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK FAQ

Yes - on request. Rated flow is published as curves rather than a single rating, so we do not state a figure here. Share your line pressure and consumption and we will confirm the exact flow data for the GFC30015MNWK from the AirTAC datasheet.

W upgrades the filter element from the 40 um standard to 5 um, and K fits a reverse (check) valve. Everything else is the standard 300-size two-unit set: PT1/2 ports, manual drain, no gauge, filter-regulator plus lubricator, with a 0.05-0.9 MPa (7-130 psi) regulator range in this manual-drain configuration.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015MNWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30015MNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.