AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$61.60 $66.81Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW

GFC30015NW is a two-unit air preparation set from the AirTAC G series: a filter regulator and a lubricator working together, so the downstream circuit gets filtered, regulated and oil-mist lubricated air from one assembly. This configuration has PT1/2 ports, a differential-pressure drain on the filter bowl and a finer 5 um filter element; the regulator setting range is 0.15-0.9 MPa (20-130 psi). Maximum working pressure is 1.0 MPa (145 psi), the operating temperature range is -5 to 70 C (non-freezing), and on the 300 size the bowls are polycarbonate. The set is ordered without a pressure gauge.

This is a genuine AirTAC part. G-series two-unit sets are available in 200, 300, 400 and 600 sizes with ports from 1/8" to 1", PT as the standard thread and G (BSPP) or NPT as catalogue options, plus a choice of drain types, 40 um or 5 um elements and gauge arrangements. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW

GFC300G-series two-unit set, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-15 filter regulator and GL300-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/2" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-15
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW Is Used

precision_manufacturing

CNC machining center tool clamping

Feeding filtered, regulated and lubricated air to the tool-clamp and chip-clearing circuits of a CNC machining center, with the 5 um element protecting fine spool valves from contamination.

factory

Furniture finishing line spray guns

Conditioning the supply to spray guns on a furniture finishing line, where the lubricator keeps trigger valves and air motors running smoothly through the shift.

conveyor_belt

Bottling conveyor diverters and stoppers

Air preparation for diverter and stopper cylinders along a bottling conveyor, with the regulator set once for consistent actuation of the gate cylinders.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW the Right Set?

Step up or down one G-series size when the port or air demand changes; the 300 size with PT1/2 suits lines fed at 1/2". The differential-pressure drain in this code works from the pressure differential across the element, while automatic or manual drains can be ordered instead. The W selects the 5 um element rather than the standard 40 um, and N means the set comes without a gauge - an external round gauge can be added if a local pressure reading is wanted.

Flow is published as curves, not a single rating, so send us your operating pressure and air demand and we will confirm the correct size against the datasheet before you order. PT is the standard thread; G (BSPP) and NPT are order options.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-15 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW FAQ

AirTAC publishes flow for this series as performance curves rather than a single rated figure, so we do not quote one number here. Send us your operating pressure and air demand and we will confirm the sizing from the datasheet on request.

It selects the 5 um filter element instead of the standard 40 um element, for finer protection of downstream valves and cylinders. The N in the code means the set is ordered without a pressure gauge; drain type and gauge options can be selected in the code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30015NW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.