verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$140.34 $147.51Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK

The AirTAC GFC two-unit set pairs a filter regulator with a lubricator, so filtration, pressure regulation and oil-mist lubrication are covered by one matched package on a compressed-air line. This GFC40010AC1WK is the size 400 frame with a 3/8 in PT port. The filter section runs a 5 um element (the W grade) with an automatic drain, the regulator section adjusts between 0.15 and 0.9 MPa (20-130 psi), and an external round gauge on a MPa scale is fitted. The K suffix adds a reverse (check) valve, which holds downstream pressure if the upstream supply dips. Maximum working pressure is 1.0 MPa (145 psi), and the unit operates from -5 to 70 C.

This is a genuine AirTAC part. The G-series spans sizes 200 to 600 with ports from 1/8 to 1 in, and the catalogue lets you choose drain type, 40 um or 5 um filtration, gauge style and scale, and thread (PT as standard, with G and NPT available to order). At this size the filter-section bowl is polycarbonate. Flow is published as curves rather than a single rating, so ask us to confirm datasheet and sizing figures for your application before ordering.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK Is Used

precision_manufacturing

Robotic welding cell

Feeds filtered, regulated and lubricated air to weld-tip clamps and valve manifolds on a spot-welding robot; the 5 um element protects the solenoid valves and the check valve holds the circuit if supply pressure dips.

conveyor_belt

Bottling-plant palletiser

Supplies conditioned, lubricated air to the gripper cylinders and case diverters on a palletiser, with the automatic drain clearing bowl condensate without shutting the line down.

factory

Injection moulding shop

Conditions the air feeding core-pull cylinders and ejector valves on injection moulding machines, where steady regulation and an oil mist help extend seal and valve life.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK the Right Set?

Work through the code from left to right: size 400 with a 3/8 in PT port sits mid-range in the G-series, so step up to 600 or down to 300 or 200 if your line's air demand points that way. Flow is published as curves, not a single number, so let us check the curve against your demand before you order. The automatic drain suits unattended or hard-to-reach installations; manual and differential-pressure drains are catalogue alternatives. Choose the 5 um element when feeding solenoid valves or precision actuators, and stay with 40 um for general protection. The round MPa gauge is external; square gauges and psi or bar scales are other options, and G or NPT threads can be ordered in place of the standard PT.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK FAQ

AirTAC publishes G-series flow as performance curves, not as a single rated figure, so we do not quote one number. Tell us your working pressure and expected air demand and we will confirm the sizing from the datasheet on request.

It selects the 5 um filter element instead of the standard 40 um grade. Choose 5 um when downstream solenoid valves or precision actuators need finer protection; 40 um remains the standard choice for general-purpose lines.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010AC1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC40010AC1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.