verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$128.99 $135.88Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W

GFC40010ALC1W is a two-unit AirTAC G-series air-treatment set: a filter-regulator plus a lubricator, filtering water and particulate from the compressed air, regulating downstream pressure and adding oil mist for tools and actuators. This 400-size set takes a PT3/8 port, has an automatic drain on the filter bowl, the 5 um (W) element for finer filtration than the standard 40 um, a round external pressure gauge with MPa scale, and the L low-pressure type regulator. Maximum working pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing. The 400-size bowls are polycarbonate.

This is a genuine AirTAC part. The same set is available with the standard 40 um element as GFC40010ALC1, and the G-series spans 200, 300, 400 and 600 sizes with 1/8 to 1 inch ports, manual, automatic or differential-pressure drains, standard or low-pressure regulator types, round or square gauges in MPa, psi or bar scales, and G (BSPP) or NPT thread options beside the standard PT. Flow is published as curves rather than a single rating, so ask us to confirm sizing figures from the datasheet on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W Is Used

science

Laboratory automation supply

Conditions the air feeding benchtop lab automation and small test-rig actuators, where the 5 um element and a low regulated setting suit sensitive downstream equipment and the lubricator protects the cylinders.

view_module

Screen printing press

Feeds the squeegee and lift cylinders on a screen printing line: filtered air protects the valve stack, a steady regulated pressure keeps print pressure repeatable, and oil mist conditions the actuators.

build

Assembly bench air tools

Serves a serviced assembly bench running air screwdrivers and riveters, with the automatic drain keeping the bowl clear and the lubricator misting the tools through the shift.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W the Right Set?

Pick the size between 200, 300, 400 and 600 against your port and air demand; this 400 with a 3/8 inch port fits mid-size supply runs. Decide the regulator type: this L code is the low-pressure type, the blank code the standard version. The automatic drain here suits unattended points; manual and differential-pressure drains are the alternatives. This W code carries the 5 um element; choose it for finer duty such as finishing work, or order the standard 40 um version where general supply filtration is enough. The round MPa gauge is ordered as coded; the embedded square gauge and psi or bar scales are the other gauge choices, and G (BSPP) or NPT threads are order options beside the standard PT. G-series flow is published as curves, not a single rating, so send us your flow requirement and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W FAQ

AirTAC publishes G-series flow as curves rather than one rated figure, so there is no single number to quote. Tell us your line pressure and the flow your application needs and we will confirm the sizing against the datasheet on request before you order.

The standard GFC filter element is 40 um; the W in this code orders the 5 um element. Specify W for finer duties such as spray finishing, lab equipment or air feeding sensitive components, and the standard 40 um version where general supply filtration is enough. Element grade, drain type and gauge can be mixed freely across the G-series.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010ALC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC40010ALC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.