verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$129.90 $136.81Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK

GFC40010C1WK is a two-piece AirTAC G-series air-treatment set: a 400-size filter-regulator paired with a lubricator, delivering filtration, pressure regulation and oil-mist lubrication from one 3/8 in (PT) connection. This configuration carries a 5 um filter element, a differential-pressure drain on the filter bowl, an external round pressure gauge reading in MPa, and a reverse (check) valve that helps hold the regulated downstream pressure against upstream dips.

It is a genuine AirTAC part. The G-series is made in 200, 300, 400 and 600 sizes with 1/8 to 1 in ports, PC (polycarbonate) bowls on the 200-400 sizes and aluminium alloy bowls at 600, a maximum working pressure of 1.0 MPa (145 psi) and a -5 to 70 C temperature range on compressed air. Flow is published as curves rather than one rated figure, so ask us and we will confirm the datasheet and sizing figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK Is Used

precision_manufacturing

CNC machining-center clamping

Filtered, regulated and lubricated air for the hydraulic-free pneumatic clamps and tool-change cylinders on a CNC machining center, with the check valve helping the set downstream pressure survive supply-line dips.

build

Automotive assembly air tools

A point-of-use set on the drop leg feeding impact wrenches and nutrunners at an automotive assembly cell, where the 5 um element protects tools and the lubricator keeps mist oil in the air stream.

view_module

Packaging machine actuation

Air preparation for the pick-and-place cylinders and sealing jaws of a carton packaging machine, with the MPa round gauge giving the operator a visible set-point reference.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK the Right Set?

Size 400 with a 3/8 in PT port sits in the middle of the G-series range: step up to 600 or down to 300/200 depending on the flow your line needs - the published curve, not a single rating, decides. The 5 um element (W option) suits finer air-quality duties; the standard element is 40 um. Drain here is the differential-pressure default, and the regulator adjusts over 0.15-0.9 MPa (20-130 psi); automatic (A) and manual (M) drain versions are also catalogue options. The gauge is the external round type on an MPa scale; embedded square gauges and psi or bar scales can be ordered, and PT is the standard thread with G (BSPP) and NPT available as options.

Because flow figures are published as curves and not a single rated number, send us your required flow and working pressure and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK FAQ

AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not quote one number here. Tell us the flow and working pressure your application needs and we will confirm the correct size against the datasheet on request before you order.

GFC pairs the filter-regulator with the lubricator in two pieces, while GC uses three separate filter, regulator and lubricator bodies. Both filter, regulate and lubricate. If you need filtering and regulating only, with no oil mist, the single-body GFR is the closer match.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010C1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC40010C1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.