verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$94.74 $100.78Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW

GFC40010LNW is a two-piece AirTAC G-series air-treatment set: a 400-size filter-regulator plus a lubricator, giving filtration, pressure regulation and oil-mist lubrication on one 3/8 in (PT) connection. The L code marks the low-pressure regulator type, W the 5 um filter element and N the gauge-delete option - there is no pressure gauge fitted, which suits panels that carry their own instrumentation.

It is a genuine AirTAC part. The G-series is built in 200, 300, 400 and 600 sizes with 1/8 to 1 in ports, PC (polycarbonate) bowls on the 200-400 sizes and aluminium alloy bowls at 600, a maximum working pressure of 1.0 MPa (145 psi) and a -5 to 70 C temperature range on compressed air. Flow is published as curves rather than one rated figure, so ask us and we will confirm the datasheet and sizing figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW Is Used

settings_input_component

Robotic palletizer gripper line

Air preparation for the vacuum and gripper circuits of a robotic palletizer whose PLC panel already displays pressure, so the gaugeless set keeps the drop leg tidy.

conveyor_belt

Conveyor sorting diverters

Filtered, regulated and lubricated air for the diverter and stopper cylinders along a parcel-sort conveyor, where set points are monitored from the central control panel.

factory

Woodworking clamp carriers

Point-of-use treatment for the pneumatic clamp carriers on a panel furniture line, with the 5 um element protecting cylinder seals and the lubricator servicing the valves.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW the Right Set?

Size 400 with a 3/8 in PT port is the G-series mid-step: choose 600 or 300/200 against the flow your circuit needs, read from the published curve rather than a single rating. With the differential-pressure drain the regulator adjusts over 0.15-0.9 MPa (20-130 psi), and L selects the low-pressure regulator type. The 5 um element is the finer option versus the 40 um standard, and the N code deletes the gauge - pick C1 (round, MPa) or the embedded square gauge with a psi or bar scale if you want a local reading. PT is the standard thread, with G (BSPP) and NPT as catalogue options.

Flow figures are published as curves, not one rated number, so send your flow and pressure requirements and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW FAQ

AirTAC publishes G-series flow as curves, not as a single rated figure, so we do not state one number here. Give us the flow and working pressure of your application and we will confirm the correct size against the datasheet on request before you order.

N deletes the pressure gauge: no gauge is supplied, so set points must be read elsewhere on the machine. If you want a local reading, order the C1 version with the external round MPa gauge, or a unit with the embedded square gauge in MPa, psi or bar scale.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010LNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC40010LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.