verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/8" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$118.55 $125.18Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W

GFC40010MC1W is a two-piece AirTAC G-series air-treatment set: a 400-size filter-regulator paired with a lubricator, combining filtration, pressure regulation and oil-mist lubrication on one 3/8 in (PT) connection. The M code selects a manual drain on the filter bowl, so condensate is emptied by hand as part of a routine; the set also carries a 5 um filter element and an external round pressure gauge reading in MPa.

It is a genuine AirTAC part. The G-series is made in 200, 300, 400 and 600 sizes with 1/8 to 1 in ports, PC (polycarbonate) bowls on the 200-400 sizes and aluminium alloy bowls at 600, a maximum working pressure of 1.0 MPa (145 psi) and a -5 to 70 C temperature range on compressed air. Flow is published as curves rather than one rated figure, so ask us and we will confirm the datasheet and sizing figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W

GFC400G-series two-unit set, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-10 filter regulator and GL400-10 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT3/8" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-10
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W Is Used

handyman

Fabrication-shop air drops

A maintenance-friendly set on the workshop air drops of a metal fabrication shop, where the manual drain suits a daily walk-round routine and the gauge shows the line set point.

bolt

Pneumatic press tooling

Prepared air for the clamps and ejection cylinders of a pneumatic press, with the 5 um element protecting close-tolerance tooling and the lubricator servicing the valve spools.

local_shipping

Trailer brake-test benches

Filter-regulated, lubricated air on the bench circuit of a commercial-vehicle workshop, where technicians drain the bowl manually between test slots.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W the Right Set?

Size 400 with a 3/8 in PT port is the G-series mid-step: go up to 600 or down to 300/200 according to the flow your line requires, judged from the published curve rather than a single rating. With the manual drain the regulator adjusts over 0.05-0.9 MPa (7-130 psi) - a wider low end than the 0.15-0.9 MPa (20-130 psi) range of the differential-pressure and automatic drain versions. The 5 um element is the finer choice against the 40 um standard, and the gauge here is the external round type on an MPa scale, with embedded square gauges and psi or bar scales orderable. PT is the standard thread; G (BSPP) and NPT are options.

Because flow is published as curves and not a single rated number, send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-10 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote one number here. Tell us the flow and working pressure your application needs and we will confirm the correct size against the datasheet on request before you order.

The M drain is emptied by hand as part of a maintenance routine. On manual-drain versions the regulator adjusts over 0.05-0.9 MPa (7-130 psi), a wider low end than the 0.15-0.9 MPa (20-130 psi) range offered with the differential-pressure and automatic drain options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40010MC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC40010MC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.