verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC600 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT3/4" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT3/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialAluminium alloy
  • Pressure gaugeFitted
  • ThreadPT
$184.38 $192.64Save 4% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W

The AirTAC GFC600 is a two-unit air-treatment set: a filter-regulator and a lubricator mounted together, so one installation removes water and particulate from the compressed air, holds a set downstream pressure, and adds oil mist for air tools and cylinders. This configuration is built for PT3/4 piping, drains automatically (the A in the code), carries the 5 um filter element (W) instead of the 40 um standard, and is fitted with an external round gauge scaled in MPa. The regulator is the standard type with a 0.15-0.9 MPa (20-130 psi) adjustment range, and at size 600 the bowls are aluminium alloy. The leading B52- marks AirTAC's copper-free (copper-prohibited) build of GFC60020AC1W, intended for lines where copper and copper alloys are not permitted, such as ammonia systems and some battery, electronics and chemical plants.

This is a genuine AirTAC part. The GFC range spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and a choice of drain type, 40 um or 5 um filtration, gauge style and scale, and PT, G or NPT threads. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rating, so ask us to confirm sizing and the datasheet, together with the exact material substitutions in the copper-free build, before ordering.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W
SeriesGFC600 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT3/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialAluminium alloy
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W

GFC600G-series two-unit set, 600 body — sets the port range.
20Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR600-20 filter regulator and GL600-20 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC600 · PT3/4" · 5 µm
One size downGFC400
Three-unit equivalentGC600-20
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W Is Used

factory

Ammonia refrigeration plant

Air preparation for pneumatic valves and actuators in an ammonia refrigeration plant, where copper and copper alloys are not permitted in the compressed-air line.

precision_manufacturing

Electronics assembly line

Feeding clean, regulated and lubricated air to pick-and-place heads and clamping cylinders on an electronics plant line that specifies copper-free components.

science

Battery cell manufacturing

Supplying treated air to pneumatic tooling and process actuators in a battery plant area where the copper-prohibited build is a line requirement.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W the Right Set?

Choose the size by port and expected flow: this is size 600 with a 3/4 in PT port, the largest step in the range (ports step 1/8, 1/4, 3/8, 1/2, 3/4 and 1 in). Drain: this unit is automatic (A); the alternatives are manual (M) and the differential-pressure default, so pick deliberately for your duty cycle. Filter grade: this one carries the 5 um element (W) rather than the 40 um standard - choose 5 um where downstream valves and instruments need finer air. Gauge: an external round gauge scaled in MPa is fitted here; the embedded square gauge and psi or bar scales are the other catalogue options. Thread is PT as standard, with G (BSPP) and NPT as order options, and a mounting bracket is included. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The aluminium-alloy bowls on the GFC600 suit harsher environments than PC bowls. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR600-20 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W FAQ

AirTAC publishes flow for the GFC600 as curves rather than a single rated figure, so we do not quote a number here. Send us your line pressure, port size and expected air consumption, and we will confirm the flow and provide the datasheet for B52-GFC60020AC1W on request.

B52- marks AirTAC's copper-free (copper-prohibited) build of GFC60020AC1W, intended for installations where copper and copper alloys are not allowed, such as ammonia systems and some battery, electronics and chemical plants. The specifications shown are shared with the base model; the exact material substitutions - and any certification question - should be confirmed with us before ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC60020AC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC60020AC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.