The AirTAC Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006LJNK is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/8" ports, ordered without a gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
GR20006LJNK is an AirTAC G-series air pressure regulator: regulation only, with no filter element and no lubricator. This is the 200 size with a PT 1/8in port, the low-pressure (L) type whose setting range extends up to 0.4 MPa, fitted with a built-in reverse/check valve (K), supplied without a gauge (N) and without a mounting bracket (J). It reduces and holds a stable downstream pressure from a compressed-air supply, with an operating temperature of -20 to 70 C.
This is a genuine AirTAC part, bought from the catalogue as an original component. The G-series regulator line runs from size 200 up to 600, with larger port sizes, PT/G/NPT thread options, standard or low-pressure regulation, gauge and reverse-valve options, and bracket choices. Because rated flow for these units is published as curves rather than a single figure, we confirm the datasheet flow numbers for your application on request.
| Model | Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20006LJNK |
|---|---|
| Series | GR200 pressure regulator |
| Port size | PT1/8" (PT thread) |
| Regulating range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure type | Low-pressure type |
| Bracket | Supplied without bracket |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR200 | G-series pressure regulator, 200 body — sets the port range. |
|---|---|
| 06 | Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4". |
| L | Low-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type. |
| J | Supplied without bracket. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR200 · PT1/8" · 0.05 - 0.4 MPa (7 - 58 psi) |
|---|---|
| One size up | GR300 |
| Line order | Filter first, then regulator, then lubricator |
Set and hold a low clamping pressure on an air-actuated clamp cylinder in a machining fixture, where the low-pressure (L) range up to 0.4 MPa is the working band and the check valve blocks backflow.
Provide a regulated low-pressure pilot line feeding solenoid or air-piloted valves, keeping the pilot circuit isolated from supply-side pressure disturbances.
Give one actuation zone of a compact production machine its own 1/8in regulated air feed, with downstream protection against reverse flow when the zone is vented.
The 200 size with a 1/8in port is the smallest step in the GR line, so match it to a circuit whose required flow sits comfortably in the low end of the G-series flow curves - step up to 300, 400 or 600 if your demand is higher. The low-pressure (L) type in this code covers regulation up to 0.4 MPa; if your setpoint needs more, order the standard type instead. The K option adds a reverse/check valve, useful where you want the downstream circuit protected against backflow; the gauge (this code has none) and thread (PT standard, G or NPT optional) are separate catalogue choices.
Because AirTAC publishes flow as curves rather than a single rated number, ask us to confirm sizing against your application before ordering.
Quick checklist
The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.
AirTAC does not publish a single rated flow figure for GR regulators - flow is given as performance curves. Send us your line pressure and air demand and we will confirm the datasheet flow figures for this exact unit on request before you order.
K selects the reverse/check valve option: the regulator is built with an internal check feature that resists backflow through the unit. The rest of the code decodes as the 200 size, PT 1/8in port, low-pressure (L) type, no bracket and no gauge.