verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GR200 · Air Pressure Regulator

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K

The AirTAC B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/4" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Pressure typeStandard type
  • Pressure gaugeFitted
  • Reflux valveFitted
  • ThreadPT
  • BracketFixing bracket included
$60.43 $65.62Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K

GR20008C1K is an AirTAC G-series air pressure regulator: regulation only, with no filter, no bowl and no lubricator. The 200 frame carries PT1/4 ports, and the trailing K means a reverse (check) valve is fitted in the supply path. Outlet pressure is read on a round external gauge with an MPa scale. Medium is compressed air.

This is a genuine AirTAC part. The GR series runs from size 200 to 600 with ports from 1/8 in to 1 in, PT thread as standard and G (BSPP) or NPT as catalogue options, in standard and low-pressure (L) types. Maximum working pressure is 1.0 MPa (145 psi) and the setting range for GR is 0.05-0.9 MPa (7-130 psi). Operating temperature is -20 to 70 C. Because flow is published as curves rather than a single rating, we confirm flow and other datasheet figures on request.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K Technical Specifications

ModelAirtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K
SeriesGR200 pressure regulator
Port sizePT1/4" (PT thread)
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
BracketFixing bracket included
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K

GR200G-series pressure regulator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type.
(blank)Fixing bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR200 · PT1/4" · 0.05 - 0.9 MPa (7 - 130 psi)
One size upGR300
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K Is Used

tune

Pneumatic clamping press

Sets and holds the working pressure on a bench pneumatic press or workholding fixture fed from a shop air main through 1/4 in drop lines, with the check valve helping hold the setting upstream.

settings_input_component

Packaging machine actuator supply

Regulates supply to small cylinders and directional valves on a packaging or labelling machine where each station needs its own set pressure.

valve

Pilot air for actuated valves

Regulates pilot pressure to pneumatically actuated process valves on a production skid, with the MPa gauge letting technicians set the pilot circuit at a glance.

Is the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K the Right Regulator?

Real choices on this series: step through sizes 200/300/400/600 to match the port and flow duty (this unit is size 200 with 1/4 in PT ports); choose the gauge and its scale (MPa, psi or bar, round external or embedded square); order G (BSPP) or NPT threads instead of PT; specify the low-pressure L type (up to 0.4 MPa) where the line runs low; and add the K check-valve option as fitted here. AirTAC publishes GR flow as curves, not a single rated figure, so ask us to confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.9 MPa (7 - 130 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K FAQ

AirTAC publishes GR-series flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the correct size and expected flow from the datasheet on request.

The trailing K means a reverse (check) valve is fitted, so air does not flow back through the regulator if upstream pressure is lost. Codes without the K are standard regulators; the rest of this code decodes as size 200, 1/4 in PT ports and a round MPa-scale gauge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008C1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GR20008C1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.