AirTAC GR200 · Air Pressure Regulator

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K

The AirTAC B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/4" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Pressure typeStandard type
  • Pressure gaugeFitted
  • Reflux valveFitted
  • ThreadPT
  • BracketSupplied without bracket
$59.53 $64.69Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K

GR20008JC1K is an AirTAC G-series air pressure regulator with a built-in reverse (check) valve, so it regulates downstream pressure while preventing backflow through the unit. It contains no filter and no lubricator - regulation only. The 200 size has a PT1/4 port (1/4 inch PT thread as standard), and this JC1K configuration includes an external round gauge scaled in MPa. Adjustment range is 0.05-0.9 MPa (7-130 psi), maximum inlet pressure is 1.0 MPa (145 psi), and operating temperature spans -20 to 70 C.

This is a genuine AirTAC part from the G-series regulator range, available in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch and G (BSPP) or NPT thread variants to order. The J in the code means no mounting bracket is included; the bracket version is a catalogue option. Flow for these regulators is published as curves rather than a single rated figure, so ask us to confirm the datasheet and sizing for your application.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K Technical Specifications

ModelAirtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K
SeriesGR200 pressure regulator
Port sizePT1/4" (PT thread)
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
BracketSupplied without bracket
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K

GR200G-series pressure regulator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR200 · PT1/4" · 0.05 - 0.9 MPa (7 - 130 psi)
One size upGR300
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K Is Used

valve

Cylinder circuit with intermittent exhaust

Regulate the feed to a double-acting cylinder circuit where the check valve stops downstream air pushing back through the regulator during valve cycling.

engineering

Clamp fixture pressure control

Hold a fixed clamping pressure on a machining or welding fixture circuit, with the MPa gauge letting operators verify the setpoint before a cycle.

settings_input_component

Manifold branch regulation

Set an isolated branch pressure on a multi-circuit manifold where the K version protects the regulator setting from back-pressure on the shared line.

Is the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K the Right Regulator?

Choose this K variant over the plain JC1 when backflow through the regulator could be a problem in your circuit - the check valve is fitted as part of the unit. The 200 size with PT1/4 port suits 1/4 inch lines; larger sizes (300/400/600) step the port and flow capacity up. The JC1 gauge reads in MPa; C2 and C3 variants give psi or bar scales. No bracket is included with the J code, and PT is the standard thread with G and NPT available to order. Since flow is published as curves, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.9 MPa (7 - 130 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K FAQ

There is no single rated flow number for this regulator - AirTAC publishes performance as flow curves. Ask us for the datasheet and we will confirm the curve data and check it against your application before you order.

The K code means a reverse (check) valve is fitted inside the unit, preventing backflow through the regulator. Everything else in the decode is the same: 200 size, PT1/4 port, round MPa gauge, no bracket, and a 0.05-0.9 MPa adjustment range.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008JC1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GR20008JC1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.