verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GR200 · Air Pressure Regulator

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1

The AirTAC B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1 is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/4" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.4 MPa (7 - 58 psi)
  • Pressure typeLow-pressure type
  • Pressure gaugeFitted
  • Reflux valveNot fitted
  • ThreadPT
  • BracketSupplied without bracket
$48.18 $53.06Save 9% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1

GR20008LJC1 belongs to AirTAC's GR regulator series: it reduces and stabilises downstream pressure on a compressed-air line, with no filtration, no bowl and no lubrication in the unit. This is the size 200 body with a PT1/4 taper port, ordered in the low-pressure L type whose set pressure tops out at 0.4 MPa. The J means no mounting bracket is supplied, and C1 specifies an external round pressure gauge scaled in MPa.

This is a genuine AirTAC part. The GR family handles compressed air at up to 1.0 MPa (145 psi) inlet and -20 to 70 C, and spans sizes 200, 300, 400 and 600 with larger ports and more flow as you step up. Options include brackets, square or round gauges in MPa, psi or bar scales, a reverse (check) valve, and G (BSPP) or NPT threads alongside the standard PT. Flow is published only as curves, so ask us to confirm sizing and the datasheet on request.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1 Technical Specifications

ModelAirtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1
SeriesGR200 pressure regulator
Port sizePT1/4" (PT thread)
Regulating range0.05 - 0.4 MPa (7 - 58 psi)
Pressure typeLow-pressure type
BracketSupplied without bracket
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1

GR200G-series pressure regulator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
LLow-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR200 · PT1/4" · 0.05 - 0.4 MPa (7 - 58 psi)
One size upGR300
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1 Is Used

settings_input_component

Robotic gripper supply

Feed a gentle, fixed pressure to the gripper cylinders of a pick-and-place robot cell so delicate parts are handled without over-clamping.

precision_manufacturing

Bench fixture clamping

Regulate air to the swing clamps on a CNC workholding fixture, holding parts at a low set pressure during light machining.

factory

Bottling line stoppers

Supply reduced-pressure air to the stopper and cap press cylinders on a small bottling line, protecting glass containers from hard impacts.

Is the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1 the Right Regulator?

Use the size/port step to match your line: 200 with PT1/4 suits compact branch circuits, while 300/400/600 increase port size and capacity - verify against the flow curves. Decide between this low-pressure L version (set up to 0.4 MPa) and the standard GR range of 0.05-0.9 MPa (7-130 psi). Pick your gauge: external round (C) or embedded square (F), scaled in MPa, psi or bar. Thread is PT as standard with G and NPT available as ordered options; J means no bracket, though GR can also be panel-mounted and bracketed versions exist. Since flow is published as curves rather than one rating, ask us to confirm sizing before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.4 MPa (7 - 58 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1 FAQ

AirTAC publishes GR flow as curves, not as a single rated number, so we deliberately do not quote a flow figure. Give us your inlet pressure, set pressure and demand, and we will confirm the right size against the datasheet curves on request.

Yes. J means this unit is supplied without a mounting bracket. Bracketed versions are available in the same size, and the GR family can also be panel-mounted. Tell us which mounting you need when ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR20008LJC1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GR20008LJC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.