AirTAC GR300 · Air Pressure Regulator

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K

The AirTAC B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT1/4" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.4 MPa (7 - 58 psi)
  • Pressure typeLow-pressure type
  • Pressure gaugeFitted
  • Reflux valveFitted
  • ThreadPT
  • BracketFixing bracket included
$64.97 $70.27Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K

The AirTAC GR series is a pure air pressure regulator: it reduces and holds a steady downstream pressure from your compressed air supply, with no filtration, no bowl and no lubrication. This GR300-08LC1K is the 300 size with a 1/4 inch PT port in the L low-pressure type, limited to a 0.4 MPa setting range for circuits that must stay at low pressure. The K suffix adds a reverse (check) valve so downstream air is held if the supply drops. An external round gauge with an MPa scale is fitted, and the mounting bracket is included.

This is a genuine AirTAC part. The G series regulators come in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch, PT as standard thread with G and NPT options to order, and an operating temperature of -20 to 70 C. AirTAC publishes regulator flow as curves rather than a single rating, so we confirm the flow and datasheet figures for your application on request.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K Technical Specifications

ModelAirtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K
SeriesGR300 pressure regulator
Port sizePT1/4" (PT thread)
Regulating range0.05 - 0.4 MPa (7 - 58 psi)
Pressure typeLow-pressure type
BracketFixing bracket included
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K

GR300G-series pressure regulator, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
LLow-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type.
(blank)Fixing bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR300 · PT1/4" · 0.05 - 0.4 MPa (7 - 58 psi)
One size downGR200
One size upGR400
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K Is Used

build

Hold circuit on an assembly press fixture

Maintains low set pressure to hold cylinders in a fixture, with the check valve keeping the downstream side pressurised during supply dips.

science

Pneumatic test rig with backflow isolation

Sets low test pressures on a QA bench while the check valve stops the tested volume pushing air back through the regulator.

conveyor_belt

Low-pressure actuation on a packaging conveyor

Feeds lightly loaded guide and divert cylinders on a conveyor line at a fixed low setting, read locally on the MPa gauge.

Is the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K the Right Regulator?

Choose the low-pressure L type when set points sit at the low end - it is limited to 0.4 MPa by design. Add the K suffix, as here, when backflow through the regulator must be blocked. The 300 body takes a 1/4 inch PT port; move to 200, 400 or 600 for other pipework. The round gauge reads in MPa; pick the LC2K code for a psi scale. G or NPT threads are catalogue options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.4 MPa (7 - 58 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K FAQ

AirTAC publishes regulator flow as characteristic curves, not as a single rated figure, so we do not quote one here. Share your set pressure and duty and we will confirm the flow from the datasheet on request.

The K adds a reverse (check) valve, so downstream air cannot push back through the regulator if the upstream supply falls. Both are the same low-pressure type, limited to a 0.4 MPa setting, with the same 1/4 inch PT port and round MPa gauge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30008LC1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GR30008LC1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.