The AirTAC GAFC Air Service Unit GAFC20008ALNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC20008ALNWK is a compact F.R.L. combination with a 1/4in port, built as a filter-regulator body paired with a lubricator on one T-bracket. It operates in the lower pressure band of 0.15-0.4 MPa (20-58 psi), uses a 5 um element, and weighs 590 g. The automatic drain clears the 25 cc condensate bowl without operator attention, while the 36 cc oil bowl feeds the lubricator.
The two-piece layout means the filter and regulator share one housing, so there is one less inter-unit joint to seal compared to a three-piece train. A reverse-flow valve is fitted, and no gauge is supplied, so the 1/8in gauge connection must be used if you need to read the set pressure. The unit is rated for -5 to 70 C and must not freeze.
| Model | Airtac GAFC Air Service Unit GAFC20008ALNWK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC200 is 1/8" if you add one.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a single-acting clamp or a small positioning jig on an assembly bench, where the 1/4in port and 5 um filtration keep the actuation clean and the 0.4 MPa ceiling prevents over-force.
Supply a laboratory test rig that uses a regulated 0.15-0.4 MPa air signal for a sensitive diaphragm valve, with the automatic drain keeping condensate out of the instrument line.
Power a portable maintenance cart with a small air drill or blow gun, where the compact 590 g body mounts easily and the lower pressure range suits light-duty tooling.
Choose this GAFC20008ALNWK when your machine needs a 1/4in port and a regulated output capped at 0.4 MPa. The L type suits delicate circuits that must never see higher pressure, but if the process may ever require more than 0.4 MPa, this is the wrong part. The 5 um element traps finer particles than the standard 40 um grade, which protects precision valves but requires more frequent element service. The automatic drain is ideal for wet or unattended lines, and the PC bowl is the default build; confirm it suits your surroundings, as the catalogue gives no material-specific data. The reverse-flow valve is fitted per the K code. Spares are orderable as GAFR200-08 and GAL200-08. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
The GAFC20008ALNWK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It has a 25 cc drain bowl and a 36 cc oil bowl, weighs 590 g, and is rated for -5 to 70 C. Use ISO VG 32 oil in the lubricator.
The N in the code after the port means no gauge is supplied. The GAFC200 body has a 1/8in gauge connection, so you can add a gauge there if you need to read the set pressure. The unit also includes a reverse-flow valve, which the catalogue shows as a separate symbol.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.