AirTAC GAFC200 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC20008ALNWK

The AirTAC GAFC Air Service Unit GAFC20008ALNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.4 MPa (20 - 58 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight590 g
$70.03 $78.44Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GAFC200-08 bowl, type and element option on one page All GAFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC20008ALNWK

This AirTAC GAFC20008ALNWK is a compact F.R.L. combination with a 1/4in port, built as a filter-regulator body paired with a lubricator on one T-bracket. It operates in the lower pressure band of 0.15-0.4 MPa (20-58 psi), uses a 5 um element, and weighs 590 g. The automatic drain clears the 25 cc condensate bowl without operator attention, while the 36 cc oil bowl feeds the lubricator.

The two-piece layout means the filter and regulator share one housing, so there is one less inter-unit joint to seal compared to a three-piece train. A reverse-flow valve is fitted, and no gauge is supplied, so the 1/8in gauge connection must be used if you need to read the set pressure. The unit is rated for -5 to 70 C and must not freeze.

Airtac GAFC Air Service Unit GAFC20008ALNWK Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC20008ALNWK
SeriesGAFC200 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.4 MPa (20 - 58 psi)
TypeLower pressure
Bowl materialPC
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight590 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC200 is 1/8" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC20008ALNWK

GAFC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
LLower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
KReverse-flow (reflux) valve attached.

Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC200 · 1/4" · curve to 1750 L/min
One size upGAFC300 (curve to 3500 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC20008ALNWK Is Used

precision_manufacturing

Precision Jig Fixtures

Feed a single-acting clamp or a small positioning jig on an assembly bench, where the 1/4in port and 5 um filtration keep the actuation clean and the 0.4 MPa ceiling prevents over-force.

science

Lab Air Circuits

Supply a laboratory test rig that uses a regulated 0.15-0.4 MPa air signal for a sensitive diaphragm valve, with the automatic drain keeping condensate out of the instrument line.

handyman

Maintenance Workstations

Power a portable maintenance cart with a small air drill or blow gun, where the compact 590 g body mounts easily and the lower pressure range suits light-duty tooling.

Is the Airtac GAFC Air Service Unit GAFC20008ALNWK the Right Air-Prep Unit?

Choose this GAFC20008ALNWK when your machine needs a 1/4in port and a regulated output capped at 0.4 MPa. The L type suits delicate circuits that must never see higher pressure, but if the process may ever require more than 0.4 MPa, this is the wrong part. The 5 um element traps finer particles than the standard 40 um grade, which protects precision valves but requires more frequent element service. The automatic drain is ideal for wet or unattended lines, and the PC bowl is the default build; confirm it suits your surroundings, as the catalogue gives no material-specific data. The reverse-flow valve is fitted per the K code. Spares are orderable as GAFR200-08 and GAL200-08. A 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 590 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC20008ALNWK FAQ

The GAFC20008ALNWK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It has a 25 cc drain bowl and a 36 cc oil bowl, weighs 590 g, and is rated for -5 to 70 C. Use ISO VG 32 oil in the lubricator.

The N in the code after the port means no gauge is supplied. The GAFC200 body has a 1/8in gauge connection, so you can add a gauge there if you need to read the set pressure. The unit also includes a reverse-flow valve, which the catalogue shows as a separate symbol.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC20008ALNWK

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC20008ALNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.