verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAFC200 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC20008ASNW

The AirTAC GAFC Air Service Unit GAFC20008ASNW is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • Bowl materialPC
  • Drainautomatic
  • Pressure gaugeNot fitted
  • Weight590 g
$59.13 $66.81Save 11% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GAFC200-08 bowl, type and element option on one page All GAFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAFC Air Service Unit GAFC20008ASNW

This 1/4in F.R.L. combination joins a filter-regulator with a lubricator on one bracket, so the air is cleaned and set to pressure in the first body, then oil mist is metered in downstream. The 5 um element traps finer particles than the standard 40 um grade, suiting precision valves or instrument circuits.

It regulates from 0.15 to 0.9 MPa (20-130 psi) with a 1.0 MPa (145 psi) maximum supply, and the automatic drain clears the 25 cc condensate bowl without an operator. The separate 36 cc oil bowl holds ISO VG 32 lubricant, and the whole unit weighs 590 g, so it needs a proper panel mount rather than tubing support.

Airtac GAFC Air Service Unit GAFC20008ASNW Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC20008ASNW
SeriesGAFC200 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade5 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialPC
Drain typeAutomatic drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight590 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC200 is 1/8" if you add one.

Model Code: Airtac GAFC Air Service Unit GAFC20008ASNW

GAFC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
(blank)Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
ADrain: Automatic drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
NNo pressure gauge; 1/8" gauge connection.
WFiltering grade 5 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC200 · 1/4" · curve to 1750 L/min
One size upGAFC300 (curve to 3500 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC20008ASNW Is Used

precision_manufacturing

Precision Fixture Clamping

Feed a single pneumatic clamp on a benchtop assembly fixture, where the 5 um element protects the clamp's fine seals and the automatic drain keeps the small 25 cc bowl from overflowing during long shifts.

science

Laboratory Air Supply

Supply a lab bench's small air cylinder or air bearing with filtered, regulated air. The 5 um element suits sensitive lab equipment, and the compact 590 g body mounts easily on a frame or panel.

handyman

Semi-Automatic Packaging Line

Run a single packaging machine's pick-and-place cylinder. The automatic drain removes condensate without stopping production, and the 1/4in port matches common small-bore valve manifolds.

Is the Airtac GAFC Air Service Unit GAFC20008ASNW the Right Air-Prep Unit?

Choose this GAFC200 when a compact 1/4in port feeds a single actuator or small jig. The automatic drain suits unattended lines, while the 5 um element demands more frequent service than a 40 um grade. No gauge is supplied, so the 1/8in gauge connection must be fitted if you need to read set pressure; the PT thread carries an MPa/psi scale on any added gauge. Spares are the GAFR200-08 filter-regulator and GAL200-08 lubricator, both orderable separately. With a 1.0 MPa max supply, you have about 0.1 MPa headroom above the 0.9 MPa top of the regulated range.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 590 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC20008ASNW FAQ

This F.R.L. combination operates from 0.15 to 0.9 MPa (20-130 psi), with a maximum pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). It works in -5 to 70 C temperatures, uses ISO VG 32 lubricant, has a 25 cc drain bowl and 36 cc oil bowl, and weighs 590 g. The 5 um filter element and automatic drain are fitted.

The N after the port code means no gauge is supplied. The GAFC200 body has a 1/8in gauge connection, so you can add a separate gauge if you need to read the set pressure. The PT thread uses an MPa/psi scale on any gauge you fit.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC20008ASNW

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAFC20008ASNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.