The AirTAC GAFC Air Service Unit GAFC20008LK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
The GAFC20008LK is a compact F.R.L. combination built as two units on one bracket: a filter-regulator body and a lubricator. Air enters the 1/4" port, gets filtered to 40 um and regulated to a lower pressure band of 0.15-0.4 MPa (20-58 psi), then the lubricator adds a metered oil mist downstream. The 590 g assembly suits small jigs and single actuators where space is tight.
The 25 cc condensate bowl and 36 cc oil bowl set the service rhythm, and the semi-auto drain dumps water each time pressure drops while the manual drain gives on-demand control. A circular gauge is fitted with an MPa/psi scale, and the reverse-flow (reflux) valve is included. The catalogue flow curve plots to 1750 L/min at 0.7 MPa inlet, useful for relative sizing.
| Model | Airtac GAFC Air Service Unit GAFC20008LK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 40 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| (blank) | Filtering grade 40 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a small pneumatic clamp on a benchtop assembly jig with regulated 0.15-0.4 MPa air, keeping force gentle on delicate parts while the lubricator protects the cylinder.
Supply a compact arbor press with filtered, regulated air at the lower pressure band, reducing the risk of over-stroking thin materials while maintaining consistent cycle force.
Drive a small pick-and-place actuator in a test rig with the 1/4" port and 0.15-0.4 MPa range, where precise low-pressure control matters more than high flow.
Choose the GAFC20008LK when your circuit needs the lower 0.15-0.4 MPa (20-58 psi) band and a 1/4" port. The PC bowl is the standard build; confirm it suits your environment since the catalogue gives no material-specific ratings. The semi-auto plus manual drain pair handles condensate without power, and the fitted gauge reads in MPa/psi for the PT thread. The 40 um element is the default; step to the 5 um W option for finer filtration. The K suffix adds the reverse-flow valve, and the two spares are GAFR200-08 and GAL200-08. For oil-free lines, omit the lubricator and select a plain GAFR instead. The 1.0 MPa max supply leaves about 0.6 MPa above the 0.4 MPa top of the range, so plan your inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
The GAFC20008LK operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C, recommended lubricant is ISO VG 32, and the unit weighs 590 g. The drain bowl holds 25 cc and the oil bowl 36 cc.
The L code sets the regulated band to 0.15-0.4 MPa (20-58 psi), which suits applications needing gentle, consistent force rather than high output. The K code adds a reverse-flow valve, shown as a separate pneumatic symbol in the catalogue. The spares are GAFR200-08 and GAL200-08.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.