The AirTAC GAFC Air Service Unit GAFC20008SWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).
This GAFC20008SWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a T-bracket with quick clamps. Air is cleaned and set to pressure in the first body, then a metered oil mist is added downstream, so the regulator seat never sees oil. With a 1/4in port and a 590 g mass, it suits compact jigs and single-actuator stations where panel space is tight.
The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 5 um element that traps finer particles than the standard 40 um grade. The 25 cc condensate bowl and 36 cc oil bowl define the service interval, and the semi-auto drain dumps on pressure drop while the manual drain works on demand. A circular gauge is fitted, reading MPa/psi for the PT thread.
| Model | Airtac GAFC Air Service Unit GAFC20008SWK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Type | Standard |
| Bowl material | PC |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| (blank) | Bowl material: PC. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| S | Standard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a small pneumatic jig or fixture with clean, regulated, lubricated air at a consistent 0.15-0.9 MPa. The 5 um element protects fine orifices in precision clamping valves.
Power one air cylinder or rotary actuator on a bench assembly station. The compact 590 g body mounts easily on a small panel or frame without straining the tubing.
Supply a short run of pneumatic screwdrivers or small presses on a light assembly line. The 25 cc condensate bowl suits moderate moisture loads, and the semi-auto drain clears on each cycle.
Choose the GAFC200 for small machines with 1/8in or 1/4in ports; the 08 code specifies 1/4in. The PC bowl is the standard build, and the catalogue gives no impact or chemical data, so confirm it suits your surroundings. The semi-auto plus manual drain pair covers both unattended pressure drops and scheduled maintenance. The 5 um element is for precision valves or instrument air, but expect more frequent element service than a 40 um grade. The PT thread carries a MPa/psi gauge scale, and the K code adds a reverse-flow valve, shown as a separate symbol in the catalogue. Spares are orderable as GAFR200-08 and GAL200-08. With a 1.0 MPa max supply, you have about 0.1 MPa above the 0.9 MPa top of the regulated band, so plan the supply pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
The GAFC20008SWK operates at 0.15-0.9 MPa (20-130 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Temperature range is -5 to 70 C. The drain bowl holds 25 cc and the oil bowl 36 cc. Use ISO VG 32 lubricant. The unit weighs 590 g.
The K code specifies a reverse-flow (reflux) valve fitted to this GAFC20008SWK. The catalogue draws it as a separate pneumatic symbol. It is an ordering difference, not a functional description, so confirm the application need from the datasheet.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.