The AirTAC GAFC Air Service Unit GAFC200C08ALWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This AirTAC GAFC200C08ALWK is a compact F.R.L. combination built from two bodies on a T bracket: a filter-regulator that cleans and sets the air pressure, plus a lubricator that adds a metered oil mist last. The 1/4in port size and 590 g mass put it in the smallest GAFC size class, suited to single actuators or small jigs where space is tight.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), with a 5 um element for finer filtration. The metal bowl holds 25 cc of condensate, while the separate oil bowl holds 36 cc. A circular gauge with an MPa/psi scale is fitted, and the automatic drain clears water without operator attention.
| Model | Airtac GAFC Air Service Unit GAFC200C08ALWK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Automatic drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| A | Drain: Automatic drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| (blank) | Circular pressure gauge fitted. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Feed a small pneumatic clamp on a benchtop assembly fixture. The 5 um element protects the clamp's fine seals, while the lower pressure range suits delicate part holding.
Supply filtered, regulated air to a single laboratory instrument that requires a gentle 0.3 MPa feed. The compact 590 g unit mounts neatly beside the bench.
Run a touch-up spray gun needing a consistent low pressure. The automatic drain keeps moisture out of the air line during intermittent use.
Choose this GAFC200C08ALWK when your circuit runs below 0.4 MPa and needs fine 5 um filtration. The metal bowl is specified by the C code; the shared specification of 1.0 MPa max and -5 to 70 C applies, so confirm the material suits your environment. The automatic drain (A) suits wet or unattended lines, while the PT thread carries an MPa/psi gauge scale. The reverse-flow valve (K) is fitted per the catalogue symbol.
For oil-free air, omit the lubricator and select a plain GAFR200-08 filter-regulator instead. Spares for this unit are the GAFR200-08 and GAL200-08, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa top of the regulated range.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates at 0.15-0.4 MPa (20-58 psi) with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C. It has a 25 cc drain bowl and a 36 cc oil bowl, weighs 590 g, and uses ISO VG 32 lubricant.
The C code specifies a metal bowl, a build choice for the unit's surroundings; the shared specification does not change with material, so confirm it suits your environment. The W code specifies a 5 um element, which traps finer particles than the standard 40 um, at the cost of more frequent element service.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.