The AirTAC GAFC Air Service Unit GAFC200C08LNWK is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 5 µm filter element and regulates 0.15 - 0.4 MPa (20 - 58 psi).
This GAFC200C08LNWK is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1/4in port and 590 g mass place it in the compact class, sized for a single actuator or a small jig rather than a machine-wide header. It carries a 5 um element, so it traps finer particles than the standard 40 um grade, and the metal bowl is specified for this build.
The lower-pressure regulator is set for 0.15-0.4 MPa (20-58 psi), which suits delicate circuits that must never see a higher regulated output. Air is filtered and regulated in the first body, then the lubricator meters oil mist into the flow last, so oil never travels back through the regulator seat. The 25 cc condensate bowl and 36 cc oil bowl are both metal, and the unit carries no gauge, leaving a 1/8in gauge connection available if one is added later.
| Model | Airtac GAFC Air Service Unit GAFC200C08LNWK |
|---|---|
| Series | GAFC200 F.R.L. combination |
| Port size | 1/4" (PT thread) |
| Filtering grade | 5 µm |
| Pressure range | 0.15 - 0.4 MPa (20 - 58 psi) |
| Type | Lower pressure |
| Bowl material | Metal |
| Drain type | Semi-auto drain + manual drain |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Capacity of drain bowl | 25 cc |
| Capacity of oil bowl | 36 cc |
| Recommended lubricant | ISO VG 32 or equivalent |
| Weight | 590 g |
Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. No gauge is supplied with this model — the gauge connection on a GAFC200 is 1/8" if you add one.
| GAFC200 | GA200 series F.R.L. unit — sets ports, bowl capacity and weight. |
|---|---|
| C | Bowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N). |
| 08 | Port size 1/4". This body offers 06 = 1/8", 08 = 1/4". |
| (blank) | Drain: Semi-auto drain + manual drain. |
| L | Lower pressure type — 0.15 - 0.4 MPa (20 - 58 psi). This body offers Standard (S) or Lower pressure (L). |
| N | No pressure gauge; 1/8" gauge connection. |
| W | Filtering grade 5 µm. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached. |
Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.
Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.
| This model | GAFC200 · 1/4" · curve to 1750 L/min |
|---|---|
| One size up | GAFC300 (curve to 3500 L/min) |
| Build order | Filter & regulator → bracket → lubricator |
Set a downstream regulator to 0.3 MPa for a delicate pneumatic clamp on a benchtop assembly fixture, where the lower-pressure range prevents over-torquing small parts.
Feed a 5 um-filtered, regulated air supply to a lab-scale sorting mechanism that handles lightweight components, with the metal bowl resisting incidental contact in a busy workspace.
Protect a small indexing table's cylinder from moisture and particulates, with the semi-auto drain clearing condensate on each shift's pressure cycle and the manual drain for scheduled checks.
Choose this GAFC200C08LNWK when your line needs fine filtration at 5 um and a regulated ceiling of 0.4 MPa - the lower-pressure type tops out there, so confirm the machine never requires more. The metal bowl is a build choice; the shared specification of 1.0 MPa max and -5 to 70 C does not change with material, so verify it suits your surroundings. The semi-auto drain dumps condensate each time pressure drops, with a manual drain for on-demand use, and the reverse-flow (reflux) valve is fitted as an ordering difference. Spares are the GAFR200-08 filter-regulator and GAL200-08 lubricator, both orderable separately. With a 1.0 MPa max supply, you have about 0.6 MPa of headroom above the 0.4 MPa regulated top, so plan the inlet pressure accordingly.
Quick checklist
The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.
This F.R.L. combination operates on air with a lower-pressure range of 0.15-0.4 MPa (20-58 psi). Maximum supply pressure is 1.0 MPa (145 psi) and proof pressure is 1.5 MPa (215 psi). It works in -5 to 70 C temperatures, uses ISO VG 32 lubricant, has a 25 cc condensate bowl and a 36 cc oil bowl, and weighs 590 g.
The C code specifies a metal bowl, which is a build choice for this unit; the catalogue does not publish impact or chemical resistance data, so confirm it fits your environment. The N after the port means no gauge is supplied, leaving a 1/8in connection if you want to add one later to read the set pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.