verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GAFC200 · F.R.L. Combination (Filter-Regulator + Lubricator)

Airtac GAFC Air Service Unit GAFC200C08S

The AirTAC GAFC Air Service Unit GAFC200C08S is a genuine two-piece F.R.L. combination — a GA-series filter & regulator and a lubricator pre-assembled on one T-shape bracket with quick mounting clamps. It has 1/4" ports, a 40 µm filter element and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination
  • Port size1/4"
  • Pressure range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • Bowl materialMetal
  • Drainsemi-auto + manual
  • Pressure gaugeCircular, MPa / psi
  • Weight590 g
$62.38 $70.27Save 11% Standard model — usually dispatched in 3-5 days
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every GAFC200-08 bowl, type and element option on one page All GAFC200-08 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac GAFC Air Service Unit GAFC200C08S

This GAFC200C08S is a two-piece F.R.L. combination: a filter-regulator body paired with a lubricator, mounted on a shared T-bracket with quick clamps. The 1/4in port and 590 g mass suit small jigs and single actuators, and the metal bowl is specified by the C code. The standard pressure range is 0.15-0.9 MPa (20-130 psi), with a 40 um element filtering the line.

The filter and regulator share one body, so air is cleaned and set to pressure before the lubricator adds oil mist downstream. The 25 cc condensate bowl and 36 cc oil bowl define the service interval, and the semi-auto drain dumps on pressure drop while the manual drain works on demand. A circular gauge is fitted, reading MPa/psi for the PT thread.

Airtac GAFC Air Service Unit GAFC200C08S Technical Specifications

ModelAirtac GAFC Air Service Unit GAFC200C08S
SeriesGAFC200 F.R.L. combination
Port size1/4" (PT thread)
Filtering grade40 µm
Pressure range0.15 - 0.9 MPa (20 - 130 psi)
TypeStandard
Bowl materialMetal
Drain typeSemi-auto drain + manual drain
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-5 to +70 °C (unfreeze)
Capacity of drain bowl25 cc
Capacity of oil bowl36 cc
Recommended lubricantISO VG 32 or equivalent
Weight590 g

Specifications follow the official AirTAC GAFC catalogue (pages 219-220). Air must not freeze in the unit. The fitted circular gauge reads in MPa / psi, set by the PT thread code.

Model Code: Airtac GAFC Air Service Unit GAFC200C08S

GAFC200GA200 series F.R.L. unit — sets ports, bowl capacity and weight.
CBowl material: Metal. Available on this body: PC (blank), Metal (C), Nylon (N).
08Port size 1/4". This body offers 06 = 1/8", 08 = 1/4".
(blank)Drain: Semi-auto drain + manual drain.
SStandard type — 0.15 - 0.9 MPa (20 - 130 psi). This body offers Standard (S) or Lower pressure (L).
(blank)Circular pressure gauge fitted.
(blank)Filtering grade 40 µm.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow valve.

Constituent units, orderable separately as spares: GAFR200-08 filter & regulator, GAL200-08 lubricator — both share this body and port. A GAFC has two units, not three: the filter and the regulator are one body.

Size Class & Flow Envelope

  • GAFC2001/8"-1/4" · 1750 L/min
  • GAFC3001/4"-1/2" · 3500 L/min
  • GAFC4003/8"-1/2" · 6000 L/min
  • GAFC5003/4" · 7000 L/min
  • GAFC6003/4"-1" · 12000 L/min

Figures are the end of the flow curve plotted in the AirTAC catalogue at 0.7 MPa inlet pressure — a sizing envelope for comparing bodies, not a rated flow. Read the catalogue curve for a real duty point. Outlet pressure falls as flow rises, so size a body with headroom above your peak demand.

This modelGAFC200 · 1/4" · curve to 1750 L/min
One size upGAFC300 (curve to 3500 L/min)
Build orderFilter & regulator → bracket → lubricator

Where the Airtac GAFC Air Service Unit GAFC200C08S Is Used

precision_manufacturing

Small jig clamping

Power a bench-mounted clamping jig with filtered and regulated air, where the metal bowl resists accidental knocks and the 1/4in port matches compact pneumatic fittings.

handyman

Single actuator feed

Feed one air cylinder on a packaging machine with a controlled oil mist, keeping the actuator lubricated while the regulator holds a stable pressure for consistent motion.

factory

Bench assembly station

Supply a hand-held air tool at a workbench, using the semi-auto drain to clear condensate automatically on each pressure drop and the manual drain for scheduled maintenance.

Is the Airtac GAFC Air Service Unit GAFC200C08S the Right Air-Prep Unit?

Choose this GAFC200C08S for a compact 1/4in line where a metal bowl is preferred. The C code specifies metal, while blank would be PC and N nylon; the common specification of 1.0 MPa max and -5 to 70 C applies to all, so confirm the material suits your surroundings. The drain is semi-auto plus manual, and the S type regulates from 0.15-0.9 MPa (20-130 psi). The 40 um element is standard; a 5 um W option traps finer particles but needs more frequent service. The PT thread carries a MPa/psi gauge scale, and the two units are orderable separately as GAFR200-08 and GAL200-08. With a 1.0 MPa max supply, there is about 0.1 MPa above the 0.9 MPa top of the range, so plan the inlet pressure if you need the full regulated output.

Quick checklist

  • ✓ Body size for your peak flow (1/4" here)
  • ✓ Standard 0.9 MPa or lower-pressure 0.4 MPa
  • ✓ Bowl material: PC (blank), Metal (C), Nylon (N)
  • ✓ Drain: semi-auto + manual, or automatic
  • ✓ Element 40 µm or 5 µm
  • ✓ Thread & gauge scale (PT / G / NPT)
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter-regulator first, lubricator last.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Fill the oil bowl with ISO VG 32 or equivalent only.
  • check Drain condensate before the 25 cc bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Support the 590 g unit on its bracket, not on the tubing.

The lubricator adds an oil mist downstream of the regulator. If any part of the line must stay oil-free, use a plain GAFR200-08 filter-regulator on that branch instead of the full combination.

Airtac GAFC Air Service Unit GAFC200C08S FAQ

The GAFC200C08S operates on air at 0.15-0.9 MPa (20-130 psi), with a max pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). The temperature range is -5 to 70 C, and the recommended lubricant is ISO VG 32. It has a 25 cc drain bowl and a 36 cc oil bowl, and weighs 590 g.

The C code specifies a metal bowl, while blank would be PC and N nylon. The catalogue lists the same 1.0 MPa max pressure and -5 to 70 C range for all three materials, so the metal bowl is a build choice rather than a performance upgrade. Confirm the material suits your environment before ordering.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Most standard models are dispatched in 3-5 days.

bolt

Fast Reply

Most inquiries answered within 7 hours.

Request a Quote for Airtac GAFC Air Service Unit GAFC200C08S

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7 hours.

Thank you. We received your request for GAFC200C08S and will confirm price, availability and lead time — usually within 7 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.