The AirTAC Airtac GAR Air Regulator GAR30008LJK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/4" ports and a built-in circular pressure gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR30008LJK is an air pressure regulator that takes a higher supply pressure and holds a steady, lower downstream pressure you set with the knob and read on the fitted circular gauge. It is a regulator only - it does not filter the air, remove water, or separate particles, and it has no drain bowl or filter element.
This lower-pressure (L) model regulates from 0.05-0.4 MPa (7-58 psi), ideal for fine low-pressure control. With a 1/4in port and 300 g mass, it suits compact pneumatic circuits. The pressed-in self-locking knob prevents the setpoint from drifting due to vibration or accidental knocks, while the balanced adjustment mechanism holds the setting as supply pressure varies.
| Model | Airtac GAR Air Regulator GAR30008LJK |
|---|---|
| Series | GAR300 air regulator |
| Port size | 1/4" (PT thread) |
| Regulation type | Lower pressure |
| Pressure range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure gauge | Circular, MPa / psi scale |
| Bracket | Not included (J) |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 300 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR300 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR300 | GA300 series air regulator — sets the port range and weight class. |
|---|---|
| 08 | Port size 1/4". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| L | Lower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure). |
| J | No bracket (J) — panel mount or existing bracket. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR300-08 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR300 · 1/4" · 300 g |
|---|---|
| One size down | GAR200 |
| One size up | GAR400 |
| Add filtration | GAFR300-08 (filter + regulator) |
Set a gentle, repeatable clamp force on delicate workpieces in assembly fixtures, where the 0.05-0.4 MPa range prevents crushing and the self-locking knob holds the setting through production vibration.
Regulate air for laboratory pneumatic controls or test rigs that need a stable low pressure, with the circular gauge giving a clear readout and the 1/4in port suiting small-bore tubing.
Feed a controlled low-pressure air supply to a spray gun or blow-off nozzle, where the balanced design keeps the outlet steady even if the shop supply fluctuates.
Choose the GAR30008LJK when you need precise regulation in the low band of 0.05-0.4 MPa (7-58 psi) - the L type gives finer resolution here but cannot reach a 0.5-0.6 MPa setpoint, so it is wrong for standard machines. This unit has no mounting bracket (J option), so plan for panel mounting or an existing bracket; the circular gauge is fitted and reads MPa/psi on the PT thread. The K code means a reverse-flow (reflux) valve is attached. If your line also needs clean air, use a GAFR300-08 or a separate GAF filter upstream - this regulator does not clean the air. The standard S type spans about 2.4x this L type's adjustable band (0.85 MPa vs 0.35 MPa).
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR300-08 filter-regulator as your air-prep needs grow.
The GAR30008LJK is a lower-pressure air regulator with a 1/4in port and 300 g weight. It regulates from 0.05-0.4 MPa (7-58 psi), with a max supply pressure of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Operating temperature is -20 to 70 C. It has a fitted circular gauge reading MPa/psi, a PT thread, no mounting bracket, and a reflux valve attached.
The L type means lower-pressure regulation from 0.05-0.4 MPa (7-58 psi), giving finer control in that low band compared to the standard S type. The K code indicates a reverse-flow (reflux) valve is attached to this unit. This regulator does not filter air - for clean air, use a GAFR or GAF upstream.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.