AirTAC GF400 · Air Filter (water separation + particulate filtration)

AirTAC GF400-10 Filter (GF40010J)

The AirTAC AirTAC GF400-10 Filter (GF40010J) is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 40 µm element, with PT3/8" ports and a differential-pressure drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizePT3/8"
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketSupplied without bracket
$37.73 $42.36Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF400 stroke, mounting and version on one page All GF400 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GF400-10 Filter (GF40010J)

GF40010J is a genuine AirTAC G-series air filter in size 400 with a 3/8 in PT port. It is a filtration-only unit for compressed air: it removes water and particulate and carries no regulator and no lubricator. This is the standard configuration: a 40 um filtering element, the differential-pressure drain as the catalogue default, and no mounting bracket (the J suffix). The bowl on the 400 size is polycarbonate, maximum working pressure is 1.0 MPa (145 psi) and the temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The G filter family runs from size 200 to 600 in ports from 1/8 in to 1 in, with the 40 um standard element or the 5 um W option, and differential-pressure, automatic or manual drains. Flow for the series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet figures for this model on request.

AirTAC GF400-10 Filter (GF40010J) Technical Specifications

ModelAirTAC GF400-10 Filter (GF40010J)
SeriesGF400 air filter
Port sizePT3/8" (PT thread)
Filtering grade40 µm
Drain typeDifferential-pressure drain
BracketSupplied without bracket
FluidCompressed air
Inlet pressure0.15 - 1.0 MPa (22 - 145 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GF400-10 Filter (GF40010J)

GF400G-series air filter, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain. Options are differential (blank), automatic (A) or manual (M).
JSupplied without bracket. A bracket ships by default; J orders it without.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF400 · PT3/8" · 40 µm
One size downGF300
One size upGF600
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GF400-10 Filter (GF40010J) Is Used

conveyor_belt

Conveyor drive air supply

Filtration at the drop feeding pneumatic cylinders and hold-down clamps on a conveyor line, using the standard 40 um grade for general plant air quality.

settings_input_component

Panel builder air inlet

The air inlet stage on a control or pneumatic panel, where the unit is piped directly between fittings without a bracket and the 40 um element handles general compressed air.

valve

Pneumatic valve manifold protection

A filter point ahead of a directional-valve manifold on a machine frame, keeping bulk water and coarse particles out of the valve stack.

Is the AirTAC GF400-10 Filter (GF40010J) the Right Filter?

Size 400 with the 3/8 in PT port suits lines built on that connection; step to 600 for larger flow demand or down to 300/200 for compact points of use, and let us check the flow curve against your application before ordering, since flow is published as curves and not as a single rating. The 40 um element is the right grade for general plant air; choose the 5 um W version where finer filtration is needed. The differential-pressure drain suits normal duty; take the automatic or manual drain option where condensate handling demands it. PT is the standard thread; G (BSPP) and NPT are catalogue thread options you can order. Add the bracket by ordering the version without the J suffix.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0.15 - 1.0 MPa (22 - 145 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 40 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

AirTAC GF400-10 Filter (GF40010J) FAQ

There is no single rated flow figure to quote: AirTAC publishes flow for the G series as curves. Tell us your application and expected duty and we will confirm the datasheet curve and check whether size 400 with a 3/8 in PT port fits, on request.

The differential-pressure drain is the catalogue default: condensate is discharged when the pressure differential across the drain reaches its trigger point during flow through the filter. If your point of use needs hands-off emptying at low flow or planned manual draining, order the automatic (A) or manual (M) drain version instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GF400-10 Filter (GF40010J)

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF40010J and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.