verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GF400 · Air Filter (water separation + particulate filtration)

AirTAC GF400-10 Filter (GF40010MW)

The AirTAC AirTAC GF400-10 Filter (GF40010MW) is a genuine G-series air filter. It separates condensed water and filters particulate from the compressed-air line through a 5 µm element, with PT3/8" ports and a manual drain. A filter does not set downstream pressure — pair it with a GR regulator, or use a GFR filter regulator, when pressure control is needed.

  • TypeAir filter
  • Port sizePT3/8"
  • Filtering grade5 µm
  • DrainManual drain
  • Inlet pressure0 - 0.9 MPa (0 - 131 psi)
  • Bowl materialPC
  • ThreadPT
  • BracketMounting bracket included
$38.89 $43.55Save 10% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GF400 stroke, mounting and version on one page All GF400 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the AirTAC GF400-10 Filter (GF40010MW)

The AirTAC GF40010MW is a GF-series air filter, 400 size, with a 3/8" PT port and a mounting bracket included. It is filtration only - water and particulate removal from compressed air, with no regulator and no lubricator. The W suffix selects the finer 5 um element in place of the standard 40 um, and the M suffix gives a manual drain that is opened by hand to empty the polycarbonate bowl.

This is a genuine AirTAC part from the GF range, which spans sizes 200 to 600 and ports from 1/8" to 1", with G (BSPP) and NPT thread options, bracket and no-bracket versions, and automatic or manual drains across the family. Flow is published as curves rather than one rated figure, so we will confirm the datasheet figures for your duty on request.

AirTAC GF400-10 Filter (GF40010MW) Technical Specifications

ModelAirTAC GF400-10 Filter (GF40010MW)
SeriesGF400 air filter
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Drain typeManual drain
BracketMounting bracket included
FluidCompressed air
Inlet pressure0 - 0.9 MPa (0 - 131 psi)
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Bowl materialPC
FeatureLow pressure loss

Specifications follow the official AirTAC G-series air-preparation data. The inlet-pressure band is set by the drain type: automatic and differential-pressure drains run 0.15 - 1.0 MPa, a manual drain runs 0 - 0.9 MPa. Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: AirTAC GF400-10 Filter (GF40010MW)

GF400G-series air filter, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain. Options are differential (blank), automatic (A) or manual (M).
(blank)Mounting bracket included. A bracket ships by default; J orders it without.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.

Field order is size, port, drain, bracket, grade, thread — a blank position takes the default. Example: GF300-10AJW is a 300 body, PT3/8", automatic drain, no bracket, 5 µm element, PT thread.

Size Class

  • GF200PT1/8" - PT1/4"
  • GF300PT1/4" - PT1/2"
  • GF400PT3/8" - PT1/2"
  • GF600PT3/4" - PT1"

A larger body carries a larger port and passes more air at the same pressure drop. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure. The GF600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGF400 · PT3/8" · 5 µm
One size downGF300
One size upGF600
Line orderFilter first, then regulator, then lubricator

Where the AirTAC GF400-10 Filter (GF40010MW) Is Used

handyman

Maintenance-shop tool wall supply

Bracket-mounted at the head of a maintenance shop's tool-air manifold, the filter conditions the feed to air ratchets, die grinders and torque tools used across the daily repair schedule.

conveyor_belt

Food-packaging carton erector

Fitted on the air feed to a carton-erecting and sealing machine, the 5 um element protects the machine's small vacuum and clamp valves from moisture and fine debris in plant air.

tune

Robot end-effector grip circuit

Installed upstream of a robot cell's gripper and blast-air circuit, it cleans the supply so the compact gripper valves and nozzles keep cycling without contamination-induced sticking.

Is the AirTAC GF400-10 Filter (GF40010MW) the Right Filter?

This code pairs the 5 um W element and manual drain with a bracketed 400 body on a 3/8" PT port - choose it when the unit will be wall or frame mounted and the line needs finer-than-standard filtration. If your air is general-purpose, the 40 um element variant saves element cost; if the filter will be unattended, look at the automatic-drain variant instead. For larger or smaller duties step to the 600 or 200/300 sizes and their matching ports. PT is the standard thread, with G and NPT orderable options.

Flow for this series is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain: differential, automatic or manual
  • ✓ Manual drain caps inlet at 0.9 MPa
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Bracket needed, or order with J
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, and follow the airflow arrow.
  • check Put the filter first in the air-preparation line.
  • check Keep inlet pressure within 0 - 0.9 MPa (0 - 131 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).
  • check Replace the 5 µm element when pressure loss rises.

The PC bowl must not be cleaned with solvents or exposed to synthetic oils that attack polycarbonate — wipe it with a dry cloth. A filter removes water and particulate only; it does not regulate pressure or add lubrication.

AirTAC GF400-10 Filter (GF40010MW) FAQ

AirTAC publishes GF-series flow as curves rather than a single rated number, so we do not state a flow figure. Give us your application details and we will confirm the datasheet flow data on request, so you can check the 400 size and 3/8" port against your demand.

GF = air filter (filtration only); 400 = frame size; 10 = 3/8" port; the missing thread letter means PT is standard; M = manual drain; W = 5 um filter element (the standard is 40 um); and no J means a mounting bracket is included. Say the word if you want the automatic-drain or no-bracket variant instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for AirTAC GF400-10 Filter (GF40010MW)

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GF40010MW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.