The AirTAC 4V100 Solenoid Valve 4V120M5FI is a genuine 5/2-way double solenoid (memory) solenoid valve with M5 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionDouble solenoid (memory)
  • Port sizeM5
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$40.70 $48.20Save 15% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V120-M5 stroke, mounting and version on one page All 4V120-M5 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V100 Solenoid Valve 4V120M5FI

The 4V120-M5FI is a double-solenoid 5/2-way pneumatic directional valve built on the compact 4V100 body, designed to direct compressed air to double-acting cylinders and actuators. Its memory-type spool stays in the last pulsed position when power is removed—held by land friction and balanced pressure, not by a spring or magnetic latch—making it ideal for sequences where a constant electrical signal is impractical. This variant ships with a 0.5 m flying wire grommet lead and a DC12V coil rated at 2.5 W.

With an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06) and a response time of 0.05 s or below, it suits ~O16-32 mm bore cylinders in benchtop automation. The M5 threaded ports keep the footprint minimal, and the IP65-rated enclosure ensures reliability in dusty or lightly washed environments. Weighing 175 g, it can be mounted individually or ganged on a manifold base for multi-axis control.

Airtac 4V100 Solenoid Valve 4V120M5FI Technical Specifications

ModelAirtac 4V100 Solenoid Valve 4V120M5FI
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionDouble solenoid (memory)
Port sizeM5
Exhaust portM5
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight175 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V100 Solenoid Valve 4V120M5FI

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
2Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-M5Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V100 Solenoid Valve 4V120M5FI Is Used

science

Lab Automation

Pulse the 4V120-M5FI to divert reagent flows or actuate a small gripper on a liquid handler. The memory hold keeps the valve in position without continuous power, minimizing heat near sensitive samples.

precision_manufacturing

Pick-and-Place Heads

Mount this 175 g valve directly on a lightweight Z-axis. The M5 ports and 0.5 m flying lead reduce bulk, while the 5/2 memory spool holds the vacuum generator or gripper state between moves.

settings_input_component

Compact Manifold Assemblies

Gang multiple 4V120-M5FI units on a base for a multi-axis test fixture. The DC12V grommet wiring and 10.2 mm² effective area provide consistent response across all stations.

Is the Airtac 4V100 Solenoid Valve 4V120M5FI the Right Valve?

Choose the 4V120-M5FI when you need a 5/2 double-solenoid valve with a memory hold and a DC12V pre-wired connection. The memory function is valuable for clamping or diverting applications where the valve must retain its state after a brief pulse, reducing coil heating and energy consumption. The grommet-style entry with a 0.5 m flying lead simplifies wiring into tight DIN-rail panels.

If your cylinder is larger than ~32 mm bore or you need a faster cycle rate, step up to the 4V200 series (Cv 1.0). For a five-point replacement match, confirm: body size (4V100), function (double solenoid 5/2), port size (M5), coil voltage (DC12V), and electrical entry (grommet lead). This model uses M5 threads, so no thread-type suffix is needed.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V100 Solenoid Valve 4V120M5FI FAQ

With a Cv of 0.6 and an effective area of10.2 mm², it comfortably operates double-acting cylinders in the ~O16-32 mm bore range at typical automation speeds. For larger cylinders or very high cycle rates, a4V200 series valve (Cv1.0) will provide faster filling and exhausting.

No. The4V120 is a double-solenoid memory valve. A brief pulse shifts the spool, and it stays there mechanically through land friction and balanced pressure when power is removed. It does not use magnetic latching or a spring return. For guaranteed load holding in a vertical axis, add a pilot-operated check valve at the cylinder ports.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V100 Solenoid Valve 4V120M5FI

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V120M5FI and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.