The AirTAC 4V100 Solenoid Valve 4V120M5FI is a genuine 5/2-way double solenoid (memory) solenoid valve with M5 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V120-M5FI is a double-solenoid 5/2-way pneumatic directional valve built on the compact 4V100 body, designed to direct compressed air to double-acting cylinders and actuators. Its memory-type spool stays in the last pulsed position when power is removed—held by land friction and balanced pressure, not by a spring or magnetic latch—making it ideal for sequences where a constant electrical signal is impractical. This variant ships with a 0.5 m flying wire grommet lead and a DC12V coil rated at 2.5 W.
With an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06) and a response time of 0.05 s or below, it suits ~O16-32 mm bore cylinders in benchtop automation. The M5 threaded ports keep the footprint minimal, and the IP65-rated enclosure ensures reliability in dusty or lightly washed environments. Weighing 175 g, it can be mounted individually or ganged on a manifold base for multi-axis control.
| Model | Airtac 4V100 Solenoid Valve 4V120M5FI |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | M5 |
| Exhaust port | M5 |
| Effective area (Cv) | 10.2 mm² (Cv 0.6) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 175 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 10.2 mm² |
|---|---|
| Flow coefficient | Cv 0.6 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -M5 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
Pulse the 4V120-M5FI to divert reagent flows or actuate a small gripper on a liquid handler. The memory hold keeps the valve in position without continuous power, minimizing heat near sensitive samples.
Mount this 175 g valve directly on a lightweight Z-axis. The M5 ports and 0.5 m flying lead reduce bulk, while the 5/2 memory spool holds the vacuum generator or gripper state between moves.
Gang multiple 4V120-M5FI units on a base for a multi-axis test fixture. The DC12V grommet wiring and 10.2 mm² effective area provide consistent response across all stations.
Choose the 4V120-M5FI when you need a 5/2 double-solenoid valve with a memory hold and a DC12V pre-wired connection. The memory function is valuable for clamping or diverting applications where the valve must retain its state after a brief pulse, reducing coil heating and energy consumption. The grommet-style entry with a 0.5 m flying lead simplifies wiring into tight DIN-rail panels.
If your cylinder is larger than ~32 mm bore or you need a faster cycle rate, step up to the 4V200 series (Cv 1.0). For a five-point replacement match, confirm: body size (4V100), function (double solenoid 5/2), port size (M5), coil voltage (DC12V), and electrical entry (grommet lead). This model uses M5 threads, so no thread-type suffix is needed.
Quick checklist
With a Cv of 0.6 and an effective area of10.2 mm², it comfortably operates double-acting cylinders in the ~O16-32 mm bore range at typical automation speeds. For larger cylinders or very high cycle rates, a4V200 series valve (Cv1.0) will provide faster filling and exhausting.
No. The4V120 is a double-solenoid memory valve. A brief pulse shifts the spool, and it stays there mechanically through land friction and balanced pressure when power is removed. It does not use magnetic latching or a spring return. For guaranteed load holding in a vertical axis, add a pilot-operated check valve at the cylinder ports.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.