The AirTAC 4V130P-06F Solenoid Valve, 5/3-way, pressure center, PT1/8, DC12V, terminal entry (4V130P06F) is a genuine 5/3-way 5/3 double solenoid — pressure center solenoid valve with PT1/8 ports and an effective area of 8.6 mm² (Cv 0.51). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V130P-06F is a 5/3-way double solenoid valve with a pressure center position, built on the compact 4V100 body platform. When both solenoids are de-energized, the spool shifts to a center position that pressurizes both cylinder ports (A and B). This applies balanced force to a double-acting piston, making it useful for applications where you need the actuator to resist external movement without a hard mechanical lock.
Operating on a 12 V DC coil drawing just 2.5 W, this terminal-entry valve is well-suited for mobile or battery-powered benchtop systems. The 1/8" PT ports deliver an effective area of 8.6 mm² (Cv 0.51, catalog figure for the 4V130C-06), correctly sizing it for small-bore cylinders in the ~Ø16-32 mm range. Like every 4V100 series valve, it features an aluminum alloy body, IP65 protection, and a sub-0.05 second response time, ensuring reliable directional control in tight automation cells.
| Model | AirTAC 4V130P-06F Solenoid Valve, 5/3-way, pressure center, PT1/8, DC12V, terminal entry (4V130P06F) |
|---|---|
| Series | 4V100 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Pressure center |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 8.6 mm² (Cv 0.51) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 200 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 8.6 mm² |
|---|---|
| Flow coefficient | Cv 0.51 |
| Response time | ≤ 0.05 s |
| Coil power | AC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 1 | Body size (4V100) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.
The pressure center position maintains a balanced clamping force on a part when the valve is at rest, preventing the workpiece from shifting during assembly or testing without requiring constant solenoid power.
Ideal for delicate pick-and-place operations where a cylinder must hold a component against a soft stop. The 12 V DC coil and 2.5 W power draw integrate easily into low-voltage control panels.
Use this valve in small-scale fluid handling or test equipment. The 8.6 mm² effective area provides smooth, controlled actuation for miniature double-acting grippers and dispensers.
Select the 4V130P-06F when your double-acting cylinder requires a controlled mid-stop that actively resists drift from external forces, a key difference from the exhaust center (float) or closed center (hydraulic lock) options. The pressure center function is particularly useful in clamping or pressing operations where you need to maintain force without continuously powering a solenoid. Ensure your system can tolerate the slight air consumption of the center position.
When ordering a replacement, confirm all five configuration points: the 4V100 body size, the 5/3 pressure-center function, the 1/8" PT port thread, the DC12V coil voltage, and the standard terminal box entry. If your cylinder is larger than 32 mm bore or you need a faster cycle rate, consider stepping up to the 4V200 series, which offers a higher Cv of 1.0. For multi-valve installations, this unit can be mounted on a 4V100-series manifold base to create a clean, integrated valve terminal.
Quick checklist
In the center (de-energized) position, both cylinder ports A and B receive supply pressure simultaneously. This creates a balanced force on a double-acting piston, allowing it to hold position against moderate external loads. It is not a safety lock; for critical load-holding, add a pilot-operated check valve.
Yes, the 'F' voltage code specifies a DC12V coil rated at 2.5 W, making it a good match for mobile robots, battery-powered test rigs, or any control system using a 12 V DC power supply. Ensure your power source can handle the inrush current.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.