The AirTAC 4V220-06C Solenoid Valve, 5/2-way, PT1/8, AC110V, terminal entry (4V22006C) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/8 ports and an effective area of 17.0 mm² (Cv 1.0). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V220-06C is a double-solenoid 5/2-way pneumatic directional valve from the AirTAC 4V200 series, built to direct compressed air to double-acting cylinders and rotary actuators. Its memory-hold spool stays in the last pulsed position without consuming holding current—ideal for circuits where you need the actuator to remain in place even if a control signal drops or the system enters a pause state.
This model carries an AC110V coil drawing 4.5 VA, wired through a standard terminal box entry. With 1/8-inch PT (Rc) tapered ports and an effective flow area of 17.0 mm² (Cv 1.0, catalog figure for the 4V210-08), it suits cylinders in the ~Ø32–50 mm range for general automation tasks. The aluminum-alloy body weighs 320 g, responds in ≤0.05 s, and holds an IP65 protection rating, making it a reliable mid-body workhorse for industrial valve banks.
| Model | AirTAC 4V220-06C Solenoid Valve, 5/2-way, PT1/8, AC110V, terminal entry (4V22006C) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 17.0 mm² (Cv 1.0) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 5 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 320 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 17.0 mm² |
|---|---|
| Flow coefficient | Cv 1.0 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
The memory-hold spool keeps a diverter gate in its last commanded position during a line stoppage or E-stop cycle, so product flow resumes predictably without a reset sequence.
Double-solenoid control holds a pneumatic clamp closed even when the PLC output is off, preventing part release during dwell or transfer—no holding current required.
Pulse the extend or retract solenoid and the 4V220-06C stays put, allowing a gripper to hold a part at mid-stroke while the machine indexes, without continuous coil power.
Step up to this 4V220-06C when your circuit needs a 5/2 valve that holds position on signal loss—unlike the spring-return 4V210, which defaults back when de-energised. The 1/8-inch port size and Cv 1.0 (catalog figure for the 4V210-08) flow capacity make it a natural fit for mid-size double-acting cylinders around Ø32–50 mm; if you are driving smaller Ø16–25 mm cylinders, the 4V100 series (Cv 0.6) often provides enough flow in a more compact footprint. For larger bores or faster cycle rates, the 4V300 body (Cv 1.65) gives you the extra throughput.
When replacing an existing valve, match five points: confirm the 4V200 body size, the double-solenoid 5/2 function, the 1/8-inch port with PT thread, the AC110V coil voltage, and the terminal-box electrical entry. If you are building a multi-valve station, this valve mounts directly onto a 4V200 manifold base, simplifying plumbing and reducing assembly time.
Quick checklist
With an effective area of 17.0 mm² (Cv 1.0, catalog figure for the 4V210-08) and a 5 cycle-per-second max frequency, this valve is well matched to double-acting cylinders in the ~Ø32–50 mm range for typical industrial stroke lengths. It provides crisp, full-flow shifting for clamps, pushers, and diverter gates without unnecessary oversizing.
The spool remains in the position it was last pulsed to, held by land friction and balanced pressure—there is no spring to return it and no magnetic latch. While this holds the actuator at its last state during a signal loss, it is not a safety brake. For suspended or vertical loads that must not drift, add a pilot-operated check valve or a dedicated mechanical brake at the cylinder ports.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.