The AirTAC 4V230E-06C Solenoid Valve, 5/3-way, exhaust center, PT1/8, AC110V, terminal entry (4V230E06C) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with PT1/8 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V230E-06C is a 5/3-way double-solenoid valve that directs compressed air to double-acting cylinders and actuators, with a specific exhaust-center spool configuration. When both solenoids are de-energized, the valve shifts to its center position where both cylinder ports are connected to exhaust, allowing the actuator to float freely. This is the ideal choice for applications where the load must be moved manually or by an external force without air resistance when the valve is at rest.
Built on the robust 4V200 aluminum-alloy body, this model is fitted with 1/8-inch PT ports and an AC110V coil drawing 4.5 VA. It delivers a Cv of 0.8 (13.6 mm² effective area) and a maximum operating frequency of 3 cycles per second. The valve weighs 360 g and includes a locking manual override, IP65 protection, and a sub-0.05-second response time, making it a reliable mid-flow pilot for assembly and clamping stations.
| Model | AirTAC 4V230E-06C Solenoid Valve, 5/3-way, exhaust center, PT1/8, AC110V, terminal entry (4V230E06C) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
Pairs perfectly with interlocked machine guards where the cylinder must dump air and go limp when the guard is opened, allowing operators to manually reposition tooling safely.
Ideal for lift-assist or clamping stations where an operator needs to push or pull the actuator rod by hand to set a custom position before the next automatic cycle.
Controls air-operated gates on conveyors where the gate must float freely to prevent product jams or damage if a package gets caught during the sorting process.
Choose this 4V230E-06C when your pneumatic circuit requires the cylinder to be completely depressurized at rest, such as when a guard door opens and the actuator must yield to manual positioning. The 4V200 body’s Cv 0.8 (catalog figure for the 4V230C-08) suits cylinders roughly in the 32 to 50 mm bore range; for smaller actuators needing a Cv of 0.6, step down to the 4V100 series, and for larger or faster-cycling bores, the 4V300 series with a Cv of 1.65 is a better match. The 5/3 center function adds a third position beyond the standard extend and retract, so ensure your control system can handle a three-position double-solenoid valve.
When replacing an existing valve, verify all five compatibility points: the 4V200 body size, the 5/3 exhaust-center function, the 1/8-inch port size with PT (Rc) tapered threads, the AC110V coil voltage, and the standard terminal box electrical entry. If you are building a multi-valve assembly, this unit can be mounted on a common manifold base to simplify plumbing and reduce potential leak points.
Quick checklist
In the center position, with neither solenoid energized, both the cylinder's A and B ports are vented to atmosphere through the exhaust ports. This means no air pressure acts on either side of the piston, so the cylinder rod can be moved freely by an external force. It is the opposite of a pressure-held or closed-center function.
Yes, the 4V200 body's effective area of 13.6 mm² (Cv 0.8, catalog figure for the 4V230C-08) provides sufficient flow for a 40 mm double-acting cylinder in typical general-purpose applications. For very high-speed cycling, ensure your operating pressure is stable and consider the valve's 3 Hz max frequency limit.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.