The AirTAC 4V230P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V230P06C) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with PT1/8 ports and an effective area of 13.6 mm² (Cv 0.8). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V230P-06C is a 5/3-way double solenoid valve with a pressure center position, designed to direct compressed air to double-acting cylinders and actuators. When both solenoids are de-energized, the spool centers and applies pressure to both cylinder ports simultaneously, which can be useful for locking a rod in place against equal force or for specific single-rod cylinder balancing circuits.
Built on the mid-flow 4V200 aluminum body, this model features a 1/8-inch PT port and an AC110V coil drawing 4.5 VA. Its 5/3 spool design yields an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08) and a maximum cycling speed of 3 cycles per second, with a response time at or below 0.05 seconds. The terminal box entry keeps wiring straightforward for standard electrical connections.
| Model | AirTAC 4V230P-06C Solenoid Valve, 5/3-way, pressure center, PT1/8, AC110V, terminal entry (4V230P06C) |
|---|---|
| Series | 4V200 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | PT1/8 |
| Exhaust port | PT1/8 |
| Effective area (Cv) | 13.6 mm² (Cv 0.8) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 360 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 13.6 mm² |
|---|---|
| Flow coefficient | Cv 0.8 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 2 | Body size (4V200) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -06 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V210 (single), 4V220 (double), 4V230C/E/P (5/3 center). Add the voltage suffix when ordering.
Ideal for circuits where a single-rod cylinder needs equal pressure on both sides at idle to counteract external forces or for specific clamping sequences that start from a pressurized neutral state.
Used in assembly jigs where a tooling plate is advanced and then held with balanced pressure, preventing drift without a full lock, suitable for light pressing or positioning tasks.
Drives a pusher arm on a sorting conveyor. The pressure center can pre-load the actuator, reducing the initial jerk when the directional shift begins, which is gentler on fragile products.
Select the 4V230P-06C when your pneumatic circuit requires a 5/3 pressure-center function on a compact 1/8-inch port base. This center condition pressurizes both cylinder lines at rest, which differs from the closed center (blocking all ports) or exhaust center (venting both sides). If your cylinder bore is below 32 mm and speed is not critical, the smaller 4V100 series (Cv 0.6) may suffice. For larger bores above 50 mm or faster actuation, step up to the 4V300 body with a Cv of 1.65.
When replacing an existing valve, match these five points: the 4V200 body size, the 5/3 pressure-center function (30P), the 1/8-inch PT thread, an AC110V coil, and the standard terminal box electrical entry. For manifold mounting, confirm the base matches the 4V200 series footprint.
Quick checklist
In the center position, both cylinder ports (A and B) receive supply pressure. This is distinct from the closed center (all ports blocked) and exhaust center (both ports vented). It can be used to hold a cylinder against balanced forces, but it does not lock the piston rod against an unbalanced load.
With an effective area of 13.6 mm2 (Cv 0.8, catalog figure for the 4V230C-08), the 4V230P-06C suits double-acting cylinders approximately in the 32 to 50 mm bore range. The 1/8-inch port is the limiting factor for flow; if your cylinder has 1/4-inch ports, consider the 4V230P-08 model for easier plumbing.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.