The AirTAC 4V320-08C Solenoid Valve, 5/2-way, PT1/4, AC110V, terminal entry (4V32008C) is a genuine 5/2-way double solenoid (memory) solenoid valve with PT1/4 ports and an effective area of 28.0 mm² (Cv 1.65). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The 4V320-08C is a 5/2-way double-solenoid directional control valve from the AirTAC 4V300 series, built to direct compressed air to double-acting cylinders and actuators. Its dual-coil memory design means the spool stays locked in the last pulsed position when both solenoids are de-energised—no spring return, no holding current required. This behaviour is ideal for applications where the actuator must hold its end-of-stroke state through a machine stop or E-stop cycle without drifting.
With an effective flow area of 28.0 mm² (Cv 1.65, catalog figure for the 4V310-10) and a max cycling rate of 4 cycles per second, this valve comfortably drives bore sizes in the ~50-80 mm range. The 4V320-08C variant is configured with 1/4-inch PT (Rc) ports and an AC110V coil drawing 4.5 VA, housed in an IP65-rated aluminium body. Response time is 0.05 seconds or less, and the spool includes a manual override for direct actuation during setup.
| Model | AirTAC 4V320-08C Solenoid Valve, 5/2-way, PT1/4, AC110V, terminal entry (4V32008C) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/2-way |
| Function | Double solenoid (memory) |
| Port size | PT1/4 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 28.0 mm² (Cv 1.65) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 4 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 400 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 28.0 mm² |
|---|---|
| Flow coefficient | Cv 1.65 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 2 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Operates pneumatic gates and diverters on conveyor lines. The memory spool holds the gate open or closed during power interruptions, preventing product jams without needing a constant signal.
Controls double-acting clamps on machining centres. The 4/cycle speed and Cv 1.65 (catalog figure for the 4V310-10) flow provide fast, firm clamping, while the double-solenoid memory keeps parts secure if the control power is cycled off.
Directs air to the main cylinder of small assembly presses. The AC110V coil integrates easily into factory power, and the IP65 enclosure withstands the dusty press environment.
Select the 4V320-08C when your circuit needs a 5/2 valve that remembers its last spool position without a continuous electrical signal. This double-solenoid memory function is a direct replacement for any 4V320-08C or equivalent 1/4-inch 5/2 double valve in the field—just match the body size (4V300), function (20), port thread (PT), and coil voltage (AC110V). If your cylinder bore is below ~40 mm, the smaller 4V200 body (Cv 1.0) may offer a more compact solution; for bores above 80 mm, step up to the 4V400 series (Cv 2.82) for faster fill times. The terminal-box entry on this model suits standard conduit wiring. For a manifold assembly, the 4V300 series can be ganged on a common base to reduce piping complexity.
Quick checklist
With an effective area of 28.0 mm² (Cv 1.65, catalog figure for the 4V310-10), it is well-matched to double-acting cylinders in the ~50-80 mm bore range for typical industrial speeds. It can drive smaller or larger bores, but actuation time will vary accordingly.
Yes. As a double-solenoid 5/2 valve, the spool is held in its last pulsed position by land friction and balanced pressure, not by a spring or magnet. It will remain in that position during a power loss, but it is not a safety-rated holding device—add a pilot-operated check valve if load holding is a safety requirement.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.