The AirTAC 4V330E-08C Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC110V, terminal entry (4V330E08C) is a genuine 5/3-way 5/3 double solenoid — closed center solenoid valve with PT1/4 ports and an effective area of 21.3 mm² (Cv 1.25). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.
The AirTAC 4V330E-08C is a 5/3-way pneumatic solenoid valve engineered for precise mid-stroke cylinder control. Its exhaust center configuration means that when both solenoids are de-energized, the cylinder ports are connected to exhaust, allowing the actuator to float freely—ideal for applications where you need to manually position a load without fighting trapped air pressure.
Built on the robust 4V300 aluminum body, this double-solenoid valve delivers a Cv of 1.25 and an effective area of 21.3 mm², making it a solid match for double-acting cylinders in the Ø50–80 mm range. The AC110V coil draws 4.5 VA, and the valve achieves a swift response time of 0.05 seconds or less, ensuring your equipment cycles reliably.
| Model | AirTAC 4V330E-08C Solenoid Valve, 5/3-way, exhaust center, PT1/4, AC110V, terminal entry (4V330E08C) |
|---|---|
| Series | 4V300 solenoid valve (spool type) |
| Valve type | 5/3-way |
| Function | 5/3 double solenoid — Closed center |
| Port size | PT1/4 |
| Exhaust port | PT1/4 |
| Effective area (Cv) | 21.3 mm² (Cv 1.25) |
| Fluid | Air (filtered by 40µm element) |
|---|---|
| Pilot type | Internal / external pilot |
| Operating pressure | 0.15 – 0.8 MPa |
| Proof pressure | 1.2 MPa |
| Max frequency | 3 cycle/sec |
| Response time | ≤ 0.05 s (activating) |
| Temperature | -20 to +70 °C |
| Body material | Aluminum alloy |
| Weight | 450 g |
Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.
| Effective area | 21.3 mm² |
|---|---|
| Flow coefficient | Cv 1.25 |
| Response time | ≤ 0.05 s |
| Coil power | AC 4.5 VA · DC24V 3.0 W · DC12V 2.5 W |
| Protection / insulation | IP65 (DIN40050), B-class |
| Voltage options | DC24V, DC12V, AC110V, AC220V |
| Manual override | Yes (locking / non-locking) |
Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.
| 4V | Solenoid valve, spool type, 4-series. |
|---|---|
| 3 | Body size (4V300) — sets port & flow. |
| 3 | Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3. |
| -08 | Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2". |
Related: 4V310 (single), 4V320 (double), 4V330C/E/P (5/3 center). Add the voltage suffix when ordering.
Controls double-acting clamps on CNC fixtures where the clamp must release fully when de-energized, allowing operators to safely load and unload parts without residual pressure.
Operates pneumatic stops on conveyor lines. The exhaust center allows the stop blade to be pushed down manually during a jam or maintenance cycle, preventing damage to the product.
Manages the cushion stroke on a small forming press. The 5/3 exhaust center lets the upper platen be manually retracted freely after an E-stop, a critical safety feature for tooling access.
Select the 4V330E-08C when your pneumatic circuit requires a 5/3-way valve with a 1/4" port and the ability to dump air from the cylinder at rest. This model is a direct fit for systems needing an AC110V supply and a terminal box connection. When sizing, step up from the 4V200 series if you need more flow than its Cv 1.0 can provide; if your cylinder bore exceeds 80 mm, the 4V400 series with a Cv of 2.82 is the better choice.
For a direct replacement, ensure your existing valve matches these five points: 4V300 body size, 5/3 exhaust-center function, 1/4" PT ports, AC110V coil voltage, and a terminal-style electrical entry. This valve can be mounted on a manifold base for multi-valve systems, simplifying plumbing and reducing potential leak points.
Quick checklist
In its neutral, de-energized state, both cylinder ports (A and B) are connected to the exhaust ports (R and S). This means no compressed air is trapped in the cylinder, so the piston rod can be moved freely by hand. It's the correct choice when you need to manually position the actuator without switching the valve.
No, the coil voltage must match your power supply exactly. This 4V330E-08C is wound for AC110V (4.5 VA). Using it with DC24V will not actuate the spool, and applying the wrong voltage can burn out the coil instantly. Always match the voltage code printed on the nameplate.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.