verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC400 · F.R.L. Combination (filter + regulator + lubricator)

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW

The AirTAC B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has PT3/8" ports, a 5 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizePT3/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$118.35 $124.97Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW

The GC40010LNW is a three-piece AirTAC G-series F.R.L. combination: a separate air filter, a pressure regulator and an oil-mist lubricator working together on one compressed-air line. This size 400 unit carries a 3/8 in PT port. The W code selects the finer 5 um filtering element, the filter bowl drains by differential pressure, no gauge is fitted, and the L code makes this the low-pressure regulator type for circuits that are set well below full line pressure. Maximum inlet pressure is 1.0 MPa (145 psi) and the working range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The G-series F.R.L. spans sizes 200 to 600 with ports from 1/8 in to 1 in, and options across the series include manual or automatic drain, a 40 um or 5 um element, embedded square or external round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads in place of the PT standard. AirTAC publishes flow as curves rather than a single rating, so ask us to confirm sizing and the datasheet for this configuration before you order.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW Technical Specifications

ModelAirtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW
SeriesGC400 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizePT3/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW

GC400G-series F.R.L. combination, 400 body — sets the port range.
10Port size PT3/8". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF400-10 filter, GR400-10 regulator and GL400-10 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC400 · PT3/8" · 5 µm
One size downGC300
One size upGC600
Two-unit equivalentGFC400-10
Build orderFilter → regulator → lubricator

Where the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW Is Used

factory

Robot weld-cell air prep

Feeding a welding robot's gripper and clamping cylinders with filtered, regulated, oil-misted air at a low set pressure, with the 5 um element protecting the valve stack from fine particulate.

tune

Paint-line spray gun supply

Conditioning the atomizing air to manual spray guns on a finishing line: water and 5 um-grade debris removed, pressure set low and steady, and a controlled oil mist carried to the gun trigger and needle.

conveyor_belt

Conveyor stopping cylinders

Supplying the pneumatic stopper and pusher cylinders along a packaging conveyor, where low regulated pressure is enough for gentle product handling and the lubricator keeps cylinder seals running smoothly.

Is the Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW the Right Station?

Size 400 with its 3/8 in port sits mid-range in the G-series; step to 600 or down to 300 if the flow curve for your line points elsewhere. The L-type low-pressure regulator is the right choice when set pressures stay low - confirm its exact adjustment ceiling with us from the datasheet. The differential-pressure drain on this unit opens in response to the pressure drop across the element; manual (M) or automatic (A) drain variants are orderable. The 5 um element suits lines where finer debris must be caught, while 40 um is the standard grade. Thread is PT as the standard, with G and NPT as orderable options, and a bracket can be specified. Because flow is published as curves, not a single rated figure, send us your application and we will confirm sizing from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR400-10 regulator with a GF400-10 filter on that branch.

Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW FAQ

AirTAC publishes G-series flow as curves rather than one rated figure, and the low-pressure L type has its own curve. Send us your line pressure and air demand and we will confirm the correct size from the datasheet before you order.

The N code in the model leaves the pressure gauge off. Gauge-equipped variants of the size 400 GC series can be ordered instead, with an embedded square gauge or an external round gauge in MPa, psi or bar scales - ask us to quote the variant you need.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GC Copper-Free Air Source Treatment Component B52-GC40010LNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GC40010LNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.