verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GR300 · Air Pressure Regulator

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K

The AirTAC B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT3/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT3/8"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Pressure typeStandard type
  • Pressure gaugeFitted
  • Reflux valveFitted
  • ThreadPT
  • BracketFixing bracket included
$64.97 $70.27Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K

GR30010C1K is a genuine AirTAC G-series air pressure regulator with a reverse (check) valve fitted: regulation only - no filter, no bowl, no lubrication. The 300-size body carries 3/8 inch PT threads, a standard adjusting range of 0.05-0.9 MPa (7-130 psi), and handles up to 1.0 MPa (145 psi) inlet at -20 to 70 C. The C1 code adds an external round gauge on an MPa scale; the K code adds the check valve that holds downstream pressure when the upstream supply is lost.

This is a genuine AirTAC part from the 200 / 300 / 400 / 600 family, available with G (BSPP) or NPT threads and panel-mount capability. Flow performance appears in the AirTAC catalogue as curves rather than a single rated figure, so we confirm the relevant datasheet values for your application on request.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K Technical Specifications

ModelAirtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K
SeriesGR300 pressure regulator
Port sizePT3/8" (PT thread)
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
BracketFixing bracket included
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K

GR300G-series pressure regulator, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type.
(blank)Fixing bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR300 · PT3/8" · 0.05 - 0.9 MPa (7 - 130 psi)
One size downGR200
One size upGR400
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K Is Used

local_shipping

Trailer air-suspension and lift circuits

Feed lift and levelling circuits on commercial-vehicle service equipment where the set pressure must stay in the circuit if the shop supply is shut off between jobs.

conveyor_belt

Conveyor gate actuation with pressure hold

Supply diverting and gating cylinders on a sorting conveyor, with the check valve retaining the regulated pressure during brief upstream supply interruptions.

build

Fixture and press tooling retrofits

Retrofit a regulated, pressure-retaining supply to clamping fixtures and small pneumatic presses, with the MPa gauge making the set point visible for tool setters.

Is the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K the Right Regulator?

Select this model when you need both a readable pressure set point and pressure retention: the C1 round MPa gauge shows the setting, and the K check valve keeps the downstream circuit charged through supply dips. If you do not need the check valve, the same unit is GR30010C1; without the gauge it is GR30008NK. PT is the standard thread with G (BSPP) and NPT as orderable options, and a bracket is included as standard (J deletes it).

For sizing, remember GR300 flow is published as curves, not a single rating - give us your demand and we will confirm the datasheet figures before you order.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.9 MPa (7 - 130 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K FAQ

AirTAC gives GR300 flow capacity as characteristic curves, not as one rated number, so we will not quote an invented figure. Tell us your port size, line pressure and demand, and we will confirm the applicable flow values from the datasheet on request.

The K code adds a reverse (check) valve: if the upstream supply fails or is shut off, downstream pressure is held instead of bleeding back. Choose GR30010C1K when the circuit must stay charged, and GR30010C1 where back-flow is not a concern.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010C1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GR30010C1K and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.