verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GR300 · Air Pressure Regulator

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1

The AirTAC B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1 is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.4 MPa (7 - 58 psi) with PT3/8" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT3/8"
  • Regulating range0.05 - 0.4 MPa (7 - 58 psi)
  • Pressure typeLow-pressure type
  • Pressure gaugeFitted
  • Reflux valveNot fitted
  • ThreadPT
  • BracketFixing bracket included
$53.63 $58.64Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1

The GR30010LC1 is an AirTAC G-series low-pressure air pressure regulator. The L in the code selects the low-pressure type, whose setting range tops out at 0.4 MPa - the right choice for circuits that must never see high pressure. This LC1 configuration is the 300 size with a PT3/8 port, an external round gauge on an MPa scale, and a mounting bracket included. It regulates only: no filter, no bowl and no lubricator.

This is a genuine AirTAC part. The GR series is offered in 200, 300, 400 and 600 sizes, standard or low-pressure types, PT/G/NPT threads, gauge or no gauge, bracket options and an optional check valve. We confirm flow and datasheet figures for this exact model on request.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1 Technical Specifications

ModelAirtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1
SeriesGR300 pressure regulator
Port sizePT3/8" (PT thread)
Regulating range0.05 - 0.4 MPa (7 - 58 psi)
Pressure typeLow-pressure type
BracketFixing bracket included
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1

GR300G-series pressure regulator, 300 body — sets the port range.
10Port size PT3/8". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
LLow-pressure type — 0.05 - 0.4 MPa (7 - 58 psi). Blank is standard, L is the low-pressure type.
(blank)Fixing bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR300 · PT3/8" · 0.05 - 0.4 MPa (7 - 58 psi)
One size downGR200
One size upGR400
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1 Is Used

science

Lab bench air supply

Give laboratory instruments, air bearings and pneumatic test rigs a gentle, clearly visible low pressure on the 3/8 in bench line, with the MPa gauge showing the setpoint at a glance.

view_module

Food packaging film handling

Regulate low-pressure air to packaging machine rollers, tension arms and web-guiding cylinders where product and film demand a soft, closely limited supply.

engineering

Instrument air take-off

Feed low-pressure pneumatic instruments and transducer lines from a plant air header, using the gauge to set and verify the reduced pressure on site.

Is the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1 the Right Regulator?

The LC1 code is the 300 size with a 3/8 port - choose it when your line sits between the 1/4 in and 1/2 in steps and your setting pressure stays within the low-pressure type's range of up to 0.4 MPa. The C1 suffix brings an external round pressure gauge reading in MPa, so the outlet setting is visible at the machine; if you prefer psi or bar scales, or a square embedded gauge, other suffixes cover those. A mounting bracket is included on this variant. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options.

Flow is published as curves, not a single rating, so ask us to confirm sizing of the GR30010LC1 against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT3/8" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.4 MPa (7 - 58 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1 FAQ

AirTAC publishes GR-series flow as curves rather than one rated figure, so we do not state a number here. Share your line pressure, set pressure and air demand, and we will confirm the flow curve and datasheet for the GR30010LC1 on request.

Three things are decoded: L selects the low-pressure type, whose adjustment range tops out at 0.4 MPa instead of the standard type's 0.05-0.9 MPa; C fits an external round pressure gauge; and 1 sets that gauge scale to MPa. The 300 size carries a PT3/8 port and a bracket is included.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30010LC1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GR30010LC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.