AirTAC GR300 · Air Pressure Regulator

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2

The AirTAC B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2 is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT1/2" ports, and ships with a pressure gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.

  • TypePressure regulator
  • Port sizePT1/2"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Pressure typeStandard type
  • Pressure gaugeFitted
  • Reflux valveNot fitted
  • ThreadPT
  • BracketSupplied without bracket
$52.72 $57.71Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2

The GR30015JC2 is an AirTAC G-series air pressure regulator: it reduces and holds downstream pressure only - no filtration, no lubrication and no drain bowl. The 300 size carries PT 1/2 in ports, and this configuration is a standard type without a mounting bracket (code J) and with a round external gauge reading in psi (code C2), suited to US shops working in imperial units. Adjustment range is 0.05-0.9 MPa with a maximum working pressure of 1.0 MPa (145 psi), for compressed air only.

This is a genuine AirTAC part. The G-series regulator family spans sizes 200, 300, 400 and 600 with ports from 1/8 in to 1 in, and can be ordered with G or NPT threads, a bracket, a square embedded gauge or a round external gauge in MPa, psi or bar scales, a low-pressure type, or a reverse/check valve. We confirm flow and datasheet figures on request.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2 Technical Specifications

ModelAirtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2
SeriesGR300 pressure regulator
Port sizePT1/2" (PT thread)
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
BracketSupplied without bracket
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-20 to +70 °C
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted
MountingPanel mounting; optional fixing bracket

Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2

GR300G-series pressure regulator, 300 body — sets the port range.
15Port size PT1/2". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type.
JSupplied without bracket.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.

Size Class

  • GR200PT1/8" - PT1/4"
  • GR300PT1/4" - PT1/2"
  • GR400PT3/8" - PT1/2"
  • GR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.

This modelGR300 · PT1/2" · 0.05 - 0.9 MPa (7 - 130 psi)
One size downGR200
One size upGR400
Line orderFilter first, then regulator, then lubricator

Where the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2 Is Used

valve

Paint booth atomizing-air branch

Holds the set atomizing pressure on a spray-booth gun supply branch where the shop already filters air upstream and only needs regulation at the point of use.

conveyor_belt

Conveyor gate-actuator station

Regulates air to divert and stopper gate cylinders along a package conveyor line, with operators reading setpoints directly in psi.

engineering

Mold core-pull cylinder supply

Sets controlled pressure for core-pull and ejector cylinders on an injection mold served by a 1/2-in pneumatic drop.

Is the Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2 the Right Regulator?

Pick the C2 code when your technicians set pressure in psi: the round external gauge is scaled 2 (psi), while MPa (1) and bar (3) scales and the square embedded gauge are the other gauge choices. The 300 size with PT 1/2 in ports suits 1/2-in plumbing; step to 400 or 600 for larger ports and flow capability. The standalone GR adjusts 0.05-0.9 MPa. PT is the standard thread, with G (BSPP) and NPT available to order, and J here means no bracket is included. Flow for the G series is published as curves, not a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Standard 0.9 MPa or low-pressure 0.4 MPa
  • ✓ Gauge fitted, or order N without
  • ✓ Gauge shape C round / F square
  • ✓ Scale MPa (1), psi (2) or bar (3)
  • ✓ Reflux valve needed, order K
Ask an Engineer

Installation & Maintenance Notes

  • check Install downstream of the filter, following the airflow arrow.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Set pressure while air is flowing, then lock the knob.
  • check Adjust within 0.05 - 0.9 MPa (7 - 130 psi) only.
  • check Operating range -20 to +70 °C.
  • check Panel-mount or use the fixing bracket; do not hang it on tubing.

Without a reflux valve, air cannot flow back through the regulator — order the K option if reverse flow is required. A regulator does not remove water or particulate; that is the filter's job.

Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2 FAQ

There is no single rated flow figure: AirTAC publishes G-series performance as flow curves. We will confirm the datasheet and curve for the GR300 size against your application on request before you order.

C2 means a round external gauge with a psi scale. C1 is the same round gauge in MPa, C3 in bar, F gives the square gauge, and N specifies no gauge. Pick the scale your team works in.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR30015JC2

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GR30015JC2 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.