The AirTAC B52-GR Copper-Free Air Source Treatment Unit B52-GR60020NK is a genuine G-series air pressure regulator. It holds a stable downstream pressure over the range 0.05 - 0.9 MPa (7 - 130 psi) with PT3/4" ports, ordered without a gauge. A regulator does not filter the air — put a GF filter upstream, or use a GFR filter regulator, when water and particulate must also be removed.
The GR60020NK is an AirTAC G-series air pressure regulator, providing downstream pressure control only - no filtration, no bowl and no lubrication. The decode is size 600 with PT3/4 ports, mounting bracket included, no gauge, and a built-in reverse (check) valve so the regulated downstream pressure is retained if the upstream supply is shut off. Adjustment range is 0.05 to 0.9 MPa (7-130 psi); maximum working pressure is 1.0 MPa (145 psi).
This is a genuine AirTAC part. The GR series runs from size 200 to 600, 1/8 in to 1 in ports, PT standard with G (BSPP) and NPT options, and gauge, bracket and check-valve choices. Flow is published as curves rather than one rated number, so we confirm flow and datasheet details on request.
| Model | Airtac B52-GR Copper-Free Air Source Treatment Unit B52-GR60020NK |
|---|---|
| Series | GR600 pressure regulator |
| Port size | PT3/4" (PT thread) |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Bracket | Fixing bracket included |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -20 to +70 °C |
| Pressure gauge | Not fitted |
| Reflux valve | Fitted (reverse flow permitted) |
| Mounting | Panel mounting; optional fixing bracket |
Specifications follow the official AirTAC G-series air-preparation data. Note the GR temperature range is -20 to +70 °C, wider than the other G-series units. A regulator has no bowl and no filter element, so there is no filtering grade. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GR600 | G-series pressure regulator, 600 body — sets the port range. |
|---|---|
| 20 | Port size PT3/4". This body offers 20 = PT3/4", 25 = PT1". |
| (blank) | Standard type — 0.05 - 0.9 MPa (7 - 130 psi). Blank is standard, L is the low-pressure type. |
| (blank) | Fixing bracket included. |
| N | No pressure gauge (N). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, type, bracket, gauge, gauge shape, scale, thread, reflux — a blank position takes the default. Example: GR300-08LNK is a 300 body, PT1/4", low-pressure type, no gauge, with reflux valve.
A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom rather than from a single rated figure.
| This model | GR600 · PT3/4" · 0.05 - 0.9 MPa (7 - 130 psi) |
|---|---|
| One size down | GR400 |
| Line order | Filter first, then regulator, then lubricator |
Holds a fixed pressure on the gates and diverters that control product flow, and the check valve keeps the gates from drifting when the line air is isolated.
Supplies impact wrenches and nutrunners at a controlled pressure so torque output stays within specification station to station.
On a multi-clamp fixture circuit, the reverse valve keeps the clamped side pressurised at its set point if the main supply drops, protecting the workpiece.
Size 600 with 3/4 in PT ports suits larger machine supply lines; sizes 200 to 400 cover 1/8 in to 1/2 in work. Pick this code over the plain GR60020N when you want the K check valve built in - it is useful on circuits where a lost supply must not vent the regulated side. The N omits the gauge; choose a gauge-coded variant if you want a built-in indication. Bracket is included. PT thread is standard, with G (BSPP) and NPT as order options; operating temperature is -20 to 70 C.
Because flow appears only as curves in the catalogue, send us your flow requirement and we will confirm the correct size on request.
Quick checklist
The reflux valve lets air flow back through the regulator, which is useful when downstream volume must vent quickly. A regulator does not remove water or particulate; that is the filter's job.
Flow for this regulator is published as performance curves, not as a single rated number, so we do not state one here. Share your application flow and pressure and we will confirm sizing and the datasheet figures on request.
K specifies a built-in reverse (check) valve: when the upstream supply fails or is shut off, it prevents downstream air from flowing back through the regulator, holding the regulated pressure. Specify K on clamp, gate or holding circuits where that retained pressure matters.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.