verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 4V Series · 5/2-way Solenoid Valve

Airtac 4V100 Solenoid Valve 4V120M5F

The AirTAC 4V100 Solenoid Valve 4V120M5F is a genuine 5/2-way double solenoid (memory) solenoid valve with M5 ports and an effective area of 10.2 mm² (Cv 0.6). It is an internally piloted spool valve that directs compressed air to double-acting cylinders and actuators.

  • Valve type5/2-way
  • FunctionDouble solenoid (memory)
  • Port sizeM5
  • Effective area10.2 mm²
  • Flow (Cv)0.6
  • Series4V100
$40.70 $48.20Save 15% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 4V120-M5 stroke, mounting and version on one page All 4V120-M5 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 4V100 Solenoid Valve 4V120M5F

The AirTAC 4V120-M5F is a 5/2-way double-solenoid directional control valve built on the compact 4V100 body. It directs compressed air to double-acting cylinders and actuators, and because it uses two solenoids with no return spring, the spool stays in its last pulsed position even when power is removed—a true memory function held by spool friction and balanced pressure, not magnetism. With M5 threaded ports and a DC12V coil drawing just 2.5 W, it’s a lightweight 175 g solution for space-constrained pneumatic circuits.

This valve delivers an effective area of 10.2 mm² (Cv 0.6, catalog figure for the 4V110-06) and can cycle up to 5 times per second. It operates on filtered air from 0.15-0.8 MPa and responds in 0.05 s or less. The IP65-rated aluminum body, manual override, and compatibility with manifold bases make it a practical choice for benchtop automation where holding the last actuator position without constant power is a design requirement.

Airtac 4V100 Solenoid Valve 4V120M5F Technical Specifications

ModelAirtac 4V100 Solenoid Valve 4V120M5F
Series4V100 solenoid valve (spool type)
Valve type5/2-way
FunctionDouble solenoid (memory)
Port sizeM5
Exhaust portM5
Effective area (Cv)10.2 mm² (Cv 0.6)
FluidAir (filtered by 40µm element)
Pilot typeInternal / external pilot
Operating pressure0.15 – 0.8 MPa
Proof pressure1.2 MPa
Max frequency5 cycle/sec
Response time≤ 0.05 s (activating)
Temperature-20 to +70 °C
Body materialAluminum alloy
Weight175 g

Specifications follow the official AirTAC 4V series datasheet. Lubrication not required. Confirm coil voltage and thread (PT / NPT / G) against the product label before wiring.

Flow & Coil Options

Effective area10.2 mm²
Flow coefficientCv 0.6
Response time≤ 0.05 s
Coil powerAC 3.5 VA · DC24V 2.8 W · DC12V 2.5 W
Protection / insulationIP65 (DIN40050), B-class
Voltage optionsDC24V, DC12V, AC110V, AC220V
Manual overrideYes (locking / non-locking)

Size the valve so effective area / Cv is not the bottleneck for your cylinder bore and speed. Undersized valves slow the actuator. Note 5/3 (center) versions have a smaller effective area than the 5/2 of the same body size.

Model Code: Airtac 4V100 Solenoid Valve 4V120M5F

4VSolenoid valve, spool type, 4-series.
1Body size (4V100) — sets port & flow.
2Function: 1 = single 5/2, 2 = double 5/2, 3 = 5/3.
-M5Port thread: M5 / 06=1/8" / 08=1/4" / 10=3/8" / 15=1/2".

Related: 4V110 (single), 4V120 (double), 4V130C/E/P (5/3 center). Add the voltage suffix when ordering.

Where the Airtac 4V100 Solenoid Valve 4V120M5F Is Used

precision_manufacturing

Pick-and-Place Grippers

The memory function holds a gripper closed on a part after a short pulse, allowing the control system to power down the solenoid between moves. This saves energy and reduces heat build-up in the 2.5 W DC12V coil during repetitive benchtop pick-and-place cycles.

science

Lab Automation Gate Valves

In analytical instruments, a 4V120-M5F can actuate a small slide gate or diverter. The double-solenoid memory ensures the gate stays in its last commanded position during a system power cycle, preventing sample cross-contamination without needing a spring-return default.

settings_input_component

Compact Indexing Tables

Use this valve to drive the stop-pin cylinder on a small rotary indexer. A pulse to one solenoid extends the pin, a pulse to the other retracts it. The M5 ports fit neatly with 4 mm push-in fittings, keeping the pneumatic layout tidy inside a small machine frame.

Is the Airtac 4V100 Solenoid Valve 4V120M5F the Right Valve?

Choose the 4V120-M5F when your application needs a compact, double-solenoid valve that retains its position after a signal pulse, eliminating the need for a continuous holding current. Its M5 ports and Cv 0.6 (catalog figure for the 4V110-06) flow capacity suit small-bore double-acting cylinders roughly in the Ø16-25 mm range. If your cylinder is larger or you need faster filling, stepping up to a 4V200-series valve (Cv 1.0) with 1/8" or 1/4" ports will provide the extra flow.

For replacement, match all five points: the 4V100 body size, the 5/2 double-solenoid (memory) function, the M5 port size, the DC12V coil voltage, and the standard terminal-box electrical entry. This valve can be used as a single unit or ganged on a 4V100 manifold base. If your control logic requires the cylinder to go to a known safe state on power loss rather than hold, consider a single-solenoid spring-return model (4V110) instead.

Quick checklist

  • ✓ Required flow (Cv) for cylinder & speed
  • ✓ Function: single / double / 5-3 center
  • ✓ Coil voltage (DC24 / AC220 …)
  • ✓ Port thread (M5 / 1/8 / 1/4 / 3/8 / 1/2)
  • ✓ Single valve or manifold base?
Ask an Engineer

Installation & Wiring Notes

  • check Use clean air filtered to 40µm or finer.
  • check Keep within 0.15 – 0.8 MPa operating pressure.
  • check Match coil voltage to your controller output.
  • check Use the manual override to test before powering.
  • check Fit silencers or fittings to the exhaust ports.
  • check Wiring by qualified personnel per AirTAC docs.

Airtac 4V100 Solenoid Valve 4V120M5F FAQ

The spool will remain in its last pulsed position, so the valve will not shift on its own. However, this is not a safety-rated holding function—normal internal leakage means a cylinder can drift over time, especially under an external load. For any suspended or vertical load that must not move, you must add a pilot-operated check valve or a mechanical brake at the cylinder ports.

Yes, the coil is rated for DC12V and consumes 2.5 W (about 0.21 A). It is designed for direct switching from a PLC transistor output or a relay. Ensure your power supply can handle the inrush and that you use a flyback diode across the coil to protect your controller from voltage spikes when the solenoid de-energises.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac 4V100 Solenoid Valve 4V120M5F

Send us the quantity, coil voltage and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for 4V120M5F and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.